19
F-14. Key disabling (Front key locking set up)
(Standard setup value: 0000)
Display data
Setting
0 0 0 0
Hold key Lock (1), Release (0)
Hi key Lock (1), Release (0)
Lo key Lock (1), Release (0)
Zero key Lock (1), Release (0)
<Set-up example>
1001 : Zero & Hold key Lock, Hi and Lo key Release
F-50.
Offset (Base
value
)
(Standard setup value : 00000)
Display data
Setting
-19999
If set to Base value and is a Zero signal , Base value is registered.
(When
Base value
10.00 , the display is 10.00 if you press ZERO button)
When setting the reference value, the comparison output operation is
not based on whether the existing display data reaches the upper limit
(RY2) or lower limit (RY1) setting value.
Based on the setting value of F-50, upper RY3, upper limit (RY2) and
lower limit (RY1) set values are operated.
~
+10000
F-51. Direction (
Direction setting, mark reverse
)
(Standard setup value : 0)
Display data
Setting
0
0
: Positive mark
1
1
:
Negative mark
(
Please confirm direction, Base input value at mark alteration
)
2
Display as absolute value