4

Electrical Requirements

 WARNING

To prevent an electric shock hazard, the power supply 

must meet the specifications stated below. It is the own-

er’s responsibility to make sure that the electrical service 

meets electrical requirements and that the electrical outlet 

has been properly installed by a licensed electrician.

• 

The cooktop is supplied with a factory installed, 42-inch 

long, power cord with a three-prong, grounding elec-

trical plug. It is connected to the chassis at the bot-

tom right rear corner (see 

Chassis Bottom Diagram

 

below). It must be connected to a dedicated, grounded 

three-prong electrical outlet installed by a licensed elec-

trician. 

• 

The electrical installation, including minimum supply 

wire size and grounding, must be done in accordance 

with National Electric Code ANSI/NFPA 70 and local 

codes and ordinances. A copy of this standard may be 

obtained from:

 

National Fire Protection Association 

 

1 Batterymarch Park  

 

Quincy, MA 02269-9101

• 

The correct voltage, frequency and amperage must be 

supplied to the electrical outlet according to the product 

data label located on the bottom of the chassis. See 

the 

Gas and Electrical Requirements

 table on this 

page for reference.

• 

Be certain to locate the electrical outlet so that the 

power cord may be easily disconnected if the unit 

requires service.

Gas Supply Requirements

• 

Be certain that the cooktop being installed is correct for 

the gas service being provided (natural gas or LP gas). 

Also, if operating the cooktop at an altitude above 4000 

ft. (1219 m) make sure it is equipped for high altitude 

operation.

• 

Units equipped for LP operation have “LP” in the 

model number listed on the product data label. See the 

Chassis Bottom Diagram

 for label location.

• 

Units equipped for high altitude operation have an “H” 

at the end of the model number listed on the product 

data label.

• 

Check your local building codes for the proper method 

of installation. In the absence of local codes, this 

appliance should be installed in accordance with the 

National Fuel Gas Code ANSI Z223.1/NFPA 54.

• 

An external manual shut-off valve must be installed 

between the gas inlet and the cooktop for the purpose 

of turning on or shutting off gas to the appliance.

• 

The cooktop comes from the factory with a regulator in 

the shipping carton. Use only the regulator provided. 

The regulator must be installed in the gas line that runs 

from the cooktop gas inlet to the gas shut off valve.

• 

The regulator inlet (female) accommodates a 3/4” gas 

line. It can also accommodate a 1/2” gas line using 

the included reducer. The inlet to the cooktop itself is 

equipped with a ½” male NPT fitting.

The cooktop gas connection is located on the bottom of the 

cooktop in the back right corner as you face the front of the 

unit. See the 

Chassis Bottom Diagram

 on this page.

DCT365S/NG

DCT365S/LP

Gas type

Natural gas

LP gas

Manifold 

pressure

5” Water  

column

10” Water 

column

Min. gas supply 

pressure *

6” Water  

column

11” Water 

column

Max. gas supply 

pressure

1/2 p.s.i.

1/2 p.s.i.

Total connected 

load

0.25 Amp.

(30 Watts)

0.25 Amp.

(30 Watts)

Circuit  

requirement

120 Vac,

60 Hz, 15 Amp.

120 Vac,

60 Hz, 15 Amp.

Gas and Electrical Requirements**

* The gas supply pressure for testing the regulator setting 

shall be at least 1 inch water column (249 Pa) above the 

specified manifold pressure.

** 

The electrical and gas data on this page is for reference 

only. If the above data does not agree with the product data 

label, use the data on the product data label.

Front of unit

Product data label

Chassis Bottom Diagram

Installation Specifications

Summary of Contents for DCT365/NG

Page 1: ...Installation Instructions Distinctive Series Cooktop Model DCT365 Part No 106927 Rev A...

Page 2: ...instructions for future reference and the local electrical inspector s use NOTE Dacor is not responsible for service required to correct a faulty installation 2010 Dacor all rights reserved If You Ne...

Page 3: ...rning TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVEN...

Page 4: ...p Do not climb on any part of the appliance warning General Safety Precautions To reduce the risk of fire electric shock serious injury or death when using this appliance follow basic safety precautio...

Page 5: ...ooktop Top panel overhang Gas inlet protudes 1 3 cm from bottom 1 4 4 cm 36 91 4 cm 2 5 1 cm countertop to cooking surface 21 53 3 cm 4 10 2 cm chassis height Product Dimensions Utility Locations Util...

Page 6: ...bel See the Chassis Bottom Diagram for label location Units equipped for high altitude operation have an H at the end of the model number listed on the product data label Check your local building cod...

Page 7: ...gas and electrical service behind it The installation must allow for the following Access to the gas shut off valve and regulator when the unit is installed Access to the electrical outlet when the c...

Page 8: ...stible side wall above countertop both sides F Vertical combustible surface Rear wall 1 5 8 min 4 1 cm Installation Specifications Cutout Dimensions Countertop Cutout Dimensions All tolerances 1 16 0...

Page 9: ...flon tape or plumber s putty on flexible gas line connections Test the gas lines for leaks as instructed before use Do not use a flame to check for leaks The maximum gas supply pressure to the regulat...

Page 10: ...tch the burner parts to the correct size and type of burner When installing the burner components make sure they are centered Twist each piece back and forth slightly until it drops completely into pl...

Page 11: ...or at least 5 minutes to allow any gas to dissipate then repeat the test Once the burner lights rotate the control knob counterclockwise from HIGH to LOW to adjust the flame height progressively On th...

Page 12: ...as service for the cooktop located and installed according to these instructions and in accordance with all applicable codes See page 4 Has the gas supply inlet pressure been measured to ensure that i...

Page 13: ...Wiring Diagram DCT365 Verify proper operation after servicing 120 Vac 60 Hz power supply warning Label all wires prior to dis connection when servicing controls Wiring errors can cause improper and da...

Page 14: ...12 Notes...