Verify Package Contents

• 

Hold down brackets (2)

• 

Grates (3)

• 

Burner sets (5)

• 

Gas pressure regulator with ¾” to ½” reducer

• 

Stainless steel cleaner

Installing the Cooktop

 WARNING

• 

Verify that the power supply meets the specifications 

on page 4 before proceeding.

• 

To prevent damage to the gas pressure regulator, 

install it only after the cooktop is mounted in its per-

manent position.

 CAUTION

• 

Do not over-tighten the hold down bolts. Over tight-

ening the hold down bolts may result in improper 

operation of the dual gas burners.

• 

Do not use a hardening compound or caulk to perma-

nently seal the cooktop into place. The cooktop must 

be readily removable if service is required. Removal 

of sealant to service the unit will be performed at the 

customer’s expense.

1.  Lower the cooktop into the cutout. Slide it forward as 

far as possible and center it side to side.  

2.  Secure the cooktop to the countertop using the two (2) 

provided hold-down brackets as shown.

Installation Instructions

Connecting the Gas Line

 WARNING

• 

Verify that the gas supply meets specifications before 

connection. See page 4.

• 

Do not install the cooktop without also installing the 

included gas regulator. Do not use the cooktop with-

out the regulator installed.

• 

Ensure that the arrow on the regulator points in the 

direction of the gas flow, towards the cooktop.

• 

Do not apply excessive pressure when tightening gas 

connections and fittings.

• 

Do not use Teflon tape or plumber’s putty on flexible 

gas line connections.

• 

Test the gas lines for leaks as instructed before use. 

Do not use a flame to check for leaks. 

• 

The maximum gas supply pressure to the regulator 

must never exceed ½ pounds per square inch (p.s.i.) 

or 3.5 kPa.

• 

The cooktop and shut-off valve must be disconnected 

from the gas supply piping system during any pres-

sure testing exceeding ½ p.s.i. (3.5 kPa).

• 

The cooktop must be isolated from the gas supply 

piping system by closing the shut-off valve to the 

cooktop during any gas supply piping system pres-

sure testing equal to or less than ½ p.s.i. (3.5 kPa).

• 

For LP gas installations, the LP gas tank must have 

its own high-pressure regulator in addition to the 

pressure regulator supplied with the cooktop.

1.  Attach the gas pressure regulator (included with the 

cooktop) to the cooktop pipe nipple inlet. For tight 

installations, the regulator may be installed upstream 

from the pipe nipple, anywhere between the shut-off 

valve and the cooktop. For best performance, minimize 

gas pressure loss by attaching the regulator as close 

as possible to the cooktop gas inlet.

2.  Complete connection of the gas supply to the cooktop 

by installing a minimum ½” flexible gas line (not includ-

ed) between the pressure regulator and the shut-off 

valve.

3.  Check for gas leaks:

◊ 

Turn all cooktop control valves to the 

OFF

 position.

◊ 

Turn on the gas supply valve and check all lines 

and connections for leaks using a soap and water 

solution or a gas leak detector.

◊ 

Turn the gas supply off.

Hold Down Bracket Installation

Power cord

Gas inlet

Hold down 

bracket mounting holes 

(both sides)

Summary of Contents for DCT365/NG

Page 1: ...Installation Instructions Distinctive Series Cooktop Model DCT365 Part No 106927 Rev A...

Page 2: ...instructions for future reference and the local electrical inspector s use NOTE Dacor is not responsible for service required to correct a faulty installation 2010 Dacor all rights reserved If You Ne...

Page 3: ...rning TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVEN...

Page 4: ...p Do not climb on any part of the appliance warning General Safety Precautions To reduce the risk of fire electric shock serious injury or death when using this appliance follow basic safety precautio...

Page 5: ...ooktop Top panel overhang Gas inlet protudes 1 3 cm from bottom 1 4 4 cm 36 91 4 cm 2 5 1 cm countertop to cooking surface 21 53 3 cm 4 10 2 cm chassis height Product Dimensions Utility Locations Util...

Page 6: ...bel See the Chassis Bottom Diagram for label location Units equipped for high altitude operation have an H at the end of the model number listed on the product data label Check your local building cod...

Page 7: ...gas and electrical service behind it The installation must allow for the following Access to the gas shut off valve and regulator when the unit is installed Access to the electrical outlet when the c...

Page 8: ...stible side wall above countertop both sides F Vertical combustible surface Rear wall 1 5 8 min 4 1 cm Installation Specifications Cutout Dimensions Countertop Cutout Dimensions All tolerances 1 16 0...

Page 9: ...flon tape or plumber s putty on flexible gas line connections Test the gas lines for leaks as instructed before use Do not use a flame to check for leaks The maximum gas supply pressure to the regulat...

Page 10: ...tch the burner parts to the correct size and type of burner When installing the burner components make sure they are centered Twist each piece back and forth slightly until it drops completely into pl...

Page 11: ...or at least 5 minutes to allow any gas to dissipate then repeat the test Once the burner lights rotate the control knob counterclockwise from HIGH to LOW to adjust the flame height progressively On th...

Page 12: ...as service for the cooktop located and installed according to these instructions and in accordance with all applicable codes See page 4 Has the gas supply inlet pressure been measured to ensure that i...

Page 13: ...Wiring Diagram DCT365 Verify proper operation after servicing 120 Vac 60 Hz power supply warning Label all wires prior to dis connection when servicing controls Wiring errors can cause improper and da...

Page 14: ...12 Notes...

Page 15: ......

Page 16: ...Dacor 600 Anton Blvd Suite 1000 Costa Mesa CA 92626 Phone 800 793 0093 Fax 626 403 3130 www Dacor com...

Reviews: