11. Install the 4 vertical supports with 16 - 4.2 x 8 mm
screws. Check everything is tightly screwed.
A
B
A. Lower vertical supports
B. 16 - 4.2 x 8 mm screws
12. Remove the 2 mounting screws from the structure.
A
A
A. 2 - Mounting screws
Electrical connection
WARNING
ELECTRICAL SHOCK HAZARD.
WARNING
DISCONNECT POWER BEFORE SERVICING.
REPLACE ALL PARTS AND PANELS BEFORE OPERATING.
FAILURE TO DO SO CAN RESULT IN DEATH OR
ELECTRICAL SHOCK.
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box cover and
install a UL listed or CSA approved ¹⁄₂” strain relief.
B
A
A. Knockout
B. Terminal box cover
4. Run home power supply cable through
strain relief, into terminal box.
A
C
D
E
F
G
B
A. Home power supply cable
B. Black wires
C. UL listed wire connectors
D. White wires
E. Green (or bare) and yellow-green ground wires
F. Power board ground wires
G. Fan ground wires
5. Use UL listed wire connectors and connect black
wires (B) together.
6. Use UL listed wire connectors and connect white
wires (D) together.