Electrical connection
WARNING
ELECTRICAL SHOCK HAZARD.
WARNING
DISCONNECT POWER BEFORE SERVICING.
REPLACE ALL PARTS AND PANELS BEFORE OPERATING.
FAILURE TO DO SO CAN RESULT IN DEATH OR
ELECTRICAL SHOCK.
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box cover and
install a UL listed or CSA approved ¹⁄₂” strain relief.
A
B
A. Terminal box cover
B. Strain relief
4. Run home power supply cable through strain relief,
into terminal box.
A. Home power supply
cable
B. UL listed or CSA
approved strain relief
C. Black wires
D. UL listed wire
connectors
E. White wires
F. Green (or bare) and
yellow-green ground
wires
A
D
B
E
C
F
5. Use UL listed wire connectors and connect black
wires (C) together.
6. Use UL listed wire connectors and connect white
wires (E) together.
WARNING
ELECTRICALLY GROUND BLOWER.
CONNECT GROUND WIRE TO GREEN AND YELLOW
GROUND WIRE IN TERMINAL BOX. FAILURE TO DO SO
CAN RESULT IN DEATH OR ELECTRICAL SHOCK.
7. Connect green (or bare) ground wire from home
power supply to yellow-green ground wire (F) in
terminal box using UL listed wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Reconnect power.