background image

8

Planning the Installation

Self-Rimming Installation With 

Downdraft Vent

• 

Only model DR30DI may be installed with a downdraft vent. 

Use only Dacor downdraft vent model ERV3015.

• 

A self-rimming countertop configuration is required for 

downdraft vent installation. On installations with a downdraft 

vent, when sliding the range into position, it will stop when the 

rear of the control panel or side panels contact the notches 

toward the front of the countertop.

• 

The self-rimming installation of the DR30DI range and 

ERV3015 downdraft vent create a “built-in” look where the 

range trim overlaps the countertop on both sides and the 

downdraft vent overlaps the countertop in back. It is also 

possible, if the cabinets are deep enough, to self rim the front 

of the range into the cabinet face immediately behind the 

control panel and door trim or behind the side panels (see 

side views on this and the facing page). The rear range trim 

will partially cover the front of the downdraft vent chassis in 

back.

Model DR30DI 

Range and 

ERV3015 

Downdraft Vent 

With

H

J

K

Countertop self-

rimmed only

20 5/8”  

(52.4 cm)

0” (0 cm) to 

3 1/4” 

(8.3 cm)

0” (0 cm) to 

5 3/8” (13.7 cm)

Countertop and 

Cabinet Front 

Self-Rimmed

,

20 5/8” *  

(52.4 cm)

NA

0” (0 cm) to 

5 3/8” (13.7 cm)

Countertop and 

Cabinet Front 

Self-Rimmed (side 

panels removed)

23 7/8” * 

(60.6 cm)

NA

0” (0 cm) to 

2 1/8” (5.4 cm)

* Cabinet face below countertop must be flush with back of notch 

in countertop.
Countertop height for all self-rimming installations:  

35 7/16” (90.0 cm) minimum, 37 7/16” (95.1 cm) maximum

IMPORTANT:

 If the 3 1/4 inch side panels are removed, the 

cabinet face must be flush with the back of the control panel.

rear wall recommended

Non-combustible

countertop opening

cabinet opening

below countertop

29 1/4” (74 3 cm)

27 1/2” (69.9 cm)

30” (76.2 cm)

2 5/8” 

(6.7 cm)

10” min.

(25.4 cm)

both sides

Countertop height: min: 35 7/16” (90.0 cm) max: 37 7/16” (95.1 cm) 

Notch countertop

overhang to width of

cabinets

3/8” min. (1.0 cm)

countertop

overhang

downdraft vent  opening

H

Combustible side

wall above range

below countertop

To cabinet face

To countertop

 front

J K

Model DR30DI/ERV3015 Countertop Self-Rimmed Only, 

Cabinet Depth: 23 5/8” to 26 7/8” 

(Without 3 1/4 Inch Side Panels Installed)

Top View

Side View

Cabinet face

Countertop

Back of

control

panel

DR30DI[H] range

3/8” min. (1.0 cm) flat countertop

overhang required behind cutout

28 3/4” (73.0 cm)

3 1/4 inch

side panel

ERV3015

downdraft

3/8” min. (1.0 cm) space

required behind ERV3015

chassis to clear stiffener

H

Range trim resting

on countertop

Cutout tolerances: +1/16” (+1.6 mm), -0

Summary of Contents for Distinctive DR30D

Page 1: ...Part No 106769 Rev H THIS APPLIANCE HAS BEEN TESTED IN ACCORDANCE WITH THE LATEST EDITIONS OF UL858 CSA C22 2 NO 61 ANSI Z21 1 STANDARDS FOR HOUSEHOLD COOKING APPLIANCES Models DR30D DR30DH DR30DI DR3...

Page 2: ...stions or problems with installation contact your Dacor dealer or the Dacor Customer Service Team For repairs to Dacor appliances under warranty call the Dacor Distinctive Service line Whenever you ca...

Page 3: ...e as a space heater to heat or warm the room Doing so may result in carbon monoxide poisoning and overheating of the appliance WARNING WARNING NEVER cover any slots holes or passages on the inside or...

Page 4: ...njured while climbing on the appliance Do not attempt to use this appliance in the event of a power failure Do not tamper with the controls Do not adjust or alter any part of the range unless specific...

Page 5: ...uit where local code permits connected to a 3 wire junction box Suggested conduit wiring color code black white red and green Using an appliance cord A 4 wire appliance cord equipped with a NEMA 14 50...

Page 6: ...rdance with the National Fuel Gas Code ANSI Z223 1 Be certain that the appliance being installed is correct for the gas service provided natural gas or LP gas Also if operating the range at an altitud...

Page 7: ...s from top of trim 46 3 8 117 8 cm 28 1 2 72 4 cm 28 7 8 73 3 cm 26 1 2 67 3 cm 24 3 8 61 9 cm 9 22 9 cm Backguard 6 15 2 cm Backguard 3 7 7 cm Backguard External handle shown some models have integra...

Page 8: ...t cabinet face MUST NOT protrude further than rear of cabinet front see Product Dimensions 4 Consult local code for exact location requirements 6 Model DR30D H 37 7 8 96 2 cm max 2 Distance to combust...

Page 9: ...Panels Installed countertop opening 29 1 4 74 3 cm 30 76 2 cm cabinet opening below countertop below countertop To cabinet face Notch countertop overhang to width of cabinets below 1 4 min 6 mm counte...

Page 10: ...abinet Front Self Rimmed 20 5 8 52 4 cm NA 0 0 cm to 5 3 8 13 7 cm Countertop and Cabinet Front Self Rimmed side panels removed 23 7 8 60 6 cm NA 0 0 cm to 2 1 8 5 4 cm Cabinet face below countertop m...

Page 11: ...K 30 76 2 cm Model DR30DI H ERV3015 Countertop and Cabinet Front Self Rimmed Cabinet Depth 26 7 8 Minimum Without 3 1 4 Inch Side Panels Installed Model DR30DI H ERV3015 Countertop and Cabinet Front S...

Page 12: ...Meat probe Dacor Stainless Steel Cleaner Literature kit Install the Anti Tip Bracket and Foot Locate the anti tip bracket included in the parts box There are two ways to mount the anti tip bracket Fl...

Page 13: ...Drill four 4 3 8 diameter countersink holes through any existing floor covering down to the concrete slab below Drill the 4 holes for the anchors 1 1 4 3 2 cm deep into the concrete slab using a 3 16...

Page 14: ...in its final position based on the product dimensions on page 5 and the actual cabinet cutout dimensions used for the installation Determine and mark the required position of the anti tip bracket base...

Page 15: ...d pull it away from the oven while continuing to lift Optional Backguard Island Trim Installation Freestanding Model DR30D H Only When used the optional island trim or optional 6 or 9 inch backguard m...

Page 16: ...ong enough to allow the range to be pulled out for service without disconnecting it from power Types of Electrical Connections Refer to the product data label see inside cover for power requirements T...

Page 17: ...rminal in the box 7 Connect the L1 wire to the L1 power supply terminal in the box 8 Connect the L2 wire to the L2 power supply terminal in the box 9 If using a 4 wire connection connect the ground wi...

Page 18: ...ction loosen the grounding screw and remove the neutral to ground jumper link from the terminal block Leave the link in place for 3 wire connections 3 Remove the nut from the conduit strain relief not...

Page 19: ...supply wire in the junction box 3 Connect the black wire from the appliance to the black L1 power supply wire in the junction box 4 Connect the red wire from the appliance to the red L2 power supply w...

Page 20: ...This is in addition to the pressure regulator provided with the range The maximum gas supply pressure to the regulator must never exceed 1 2 pound per square inch psi or 3 5 kPa The range and shut of...

Page 21: ...ps over the lower lip of each hinge receptacle 2 Lower the door to the fully opened position 3 Rotate the two hinge locks toward the oven 4 Slowly and carefully open and close the door completely to e...

Page 22: ...y three 3 minutes the oven should begin to heat Press the CANCEL SECURE key to stop the oven heating process NOTES If either the oven or cooktop does not operate properly follow these troubleshooting...

Page 23: ......

Page 24: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com...

Reviews: