Installation requirements
•
Connect directly to the circuit-breaker box (or fused disconnect) through the
flexible, armored or nonmetallic sheathed, copper cable with grounding wire. (See
Electrical connection
.)
•
Flexible conduit from the oven should be connected directly to the junction box.
•
Fuse both sides of the line.
•
Do not cut the conduit. The conduit length lets the oven be pulled out for service.
•
A UL-listed or CSA-approved conduit connector must be provided.
•
If the house has aluminum wiring:
– connect a section of solid copper wire to the ends of the flexible conduit leads.
– connect the aluminum wiring to the added section of copper wire using special
connectors/tools designed and UL-listed for joining copper to aluminum.
•
Follow the electrical connector manufacturer’s recommended procedure.
Aluminum/copper connection must comply with local codes and industry-accepted
wiring practices.
For power requirement for model DOC30M977D refer to the following table.
Model
240 VAC
208 VAC
DOC30M977D*
8.9 kW
6.7 kW