16
Installation Instructions
Verifying Proper Operation
WARNING
Before operating the range, read the accompanying use
and care manual completely.
1. Before beginning the test procedure, make
sure all range control valves are in the
“OFF”
position, and all burner rings, burner caps and
grates are properly positioned on the spill tray.
2. Turn on the gas supply at the shut-off valve.
3. Connect the power cord to the electrical outlet. When
the range is first connected, the oven indicator light
flashes on and off for about 10 seconds while the
range’s circuitry starts up. Wait for the light to stop
flashing before going to step 4.
4. Test the left front burner on the cooktop
by pushing in and turning the control knob
counterclockwise to the
HIGH
position.
The igniter for the left front burner will
spark continuously. It may take up to 4
seconds for the burner to ignite, at which time the
ignitor will stop sparking. If ignition does not occur
within 4 seconds, turn off the knob, wait for at least 5
minutes to allow any gas to dissipate, then repeat this
ignition test. When the burner ignites, rotate the knob
counterclockwise from
HIGH
to
LOW
to adjust the
flame height progressively. When installed properly,
the flame will be steady. It will also have a sharp, blue
inner cone that will vary in length proportional to the
burner size. LP gas units may have small yellow tips at
the end of the flames, which is normal.
5. Repeat ignition test for the remaining cooktop burners.
Make sure the knobs light when in the
HIGH
position.
6. After testing all the cooktop burners, turn them all off.
7. Open the oven door. Test the oven light by turning on
the light switch on the right side of the control panel.
8. Turn on the convection fan switch. You should hear the
convection fan, located behind the screen at the back
of the oven, come on.
9. With the oven door open, turn the oven control knob
to the 400 degree position. Both the knob itself and
the oven ON indicator light next to the knob should
illuminate. Within 60 seconds you should hear the bake
burner ignite below the oven floor. It should begin to
give off heat.
10. Turn the oven control knob to the
BROIL
position. The
bake burner should turn off. Both the oven control knob
and the oven
ON
indicator light should be illuminated.
Within 60 seconds the broil burner on the ceiling of the
oven should ignite and begin to give off heat.
11. Turn the oven knob to the
OFF
position.
If the range does not operate properly, follow these
troubleshooting steps:
1. Verify that the circuit breaker for the range electrical
outlet is on and not tripped. Make sure the power cord
is connected.
2. Make sure the gas supply valve is in the on position
and that the main gas valve to the building is open.
3. Check to see if the oven burner light flashes on and
off once a second. If it does, repair by an authorized
service technician is required.
4. Repeat the above tests.
5. If the appliance still does not work, contact Dacor
Distinctive Service at (800) 793-0093 ex. 2822. Do not
attempt to repair the appliance yourself. Dacor is not
responsible for the cost of correcting problems caused
by a faulty installation.
OFF
HIGH
Normal Flame