background image

7

Cabinet Depth Greater Than 24” 

Partial Side Panels Installed, Range Back Overhanging 

Countertop (Top View)

2

Cabinet Depth Greater Than 25 1/8” 

Partial Side Panels Removed, Range Back Overhanging 

Countertop (Top View)

2

Cabinets Less Than 24” Deep, 

Partial Side Panels Installed, Range Back Flush to Wall 

(Top View)

Cabinet Exactly 24” Deep, 

Partial Side Panels Removed, Range Back Flush to 

Wall (Top View)

Non-combustible  

rear wall required 

countertop opening

29 1/4” (74.3 cm)

30” (76.2 cm)

cabinet opening

below countertop

below countertop

Countertop front

Cabinet face

Notch countertop

to width of cabinets 

10” min. (25.4 cm)

to any combustibles 

above counter both sides

21” 

 (53.3 cm)

to

24”

(61.0 cm)

20 3/4”

 (52.7 cm)

25 5/8”

max. 

(65.1 cm)

countertop opening

29 1/4” (74.3 cm)

30” (76.2 cm)

cabinet opening

below countertop

below countertop

Cabinet face

Notch countertop

overhang to width of

cabinets

10” min. (25.4 cm)

to any combustibles 

above counter both sides

Countertop overhang 

1 5/8” (4.1 cm) max. 

24”

 (61.0 cm)

Non-combustible

rear wall required

Rear wall or

countertop edge

countertop opening

29 1/4” (74.3 cm)

30” (76.2 cm)

cabinet opening

below countertop

below countertop

Cabinet face

Notch countertop

to width of cabinets 

3/4” min. (1.9 cm)

 countertop overhang

10” min. (25.4 cm)

to any combustibles 

above counter both sides

21 1/8”

 (53.7 cm)

to

24 1/8”

 (61.3 cm)

20 7/8”

 (53.0 cm)

25 3/4”

 (65.4 cm)

max.

Countertop front

Rear wall or

countertop edge

countertop opening

29 1/4” (74.3 cm)

30” (76.2 cm)

cabinet opening

below countertop

below countertop

Cabinet face

Notch countertop

overhang to width of

cabinets

1” min. (2.5 cm)

 Countertop overhang

10” min. (25.4 cm)

to any combustibles 

above counter both sides

Countertop overhang 

1 5/8” (4.1 cm) max. 

24 1/8”

 (61.3 cm)

1 On models DR30GIS and DR30GIS, a non-combustible surface required immediately behind range, as specified on facing page, 

when the back of the backguard is less than 2 1/2” (6.4 cm) from rear wall. 

2 Included rear self-rimming trim piece must be installed to cover the edge of the countertop in back.

3 To create a “built-in look” on the front of the cabinet, this dimension may be changed to 29 1/4” (74.3 cm), with the width at the 

notches remaining 30”. This configuration is only for models DR30GIS and DR30GIFS with the side panels removed.

Countertop  height:  34  3/4”  (88.3  cm)  min.                                 

 

 

    

 

36 7/8” (93.7 cm) max. 

Countertop thickness: 1 5/8” (4.1 cm) max.

For all self-rimming installations (without raised vent):

Installation Specifications

Self-Rimming Installation Cutout Options (Models DR30GIS and DR30GIFS Only)

3

3

1

1

1

1

Summary of Contents for DR30GS

Page 1: ...tive 30 Inch Gas Range Part No 105908 Rev D THIS APPLIANCE HAS BEEN TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI Z21 1a 2011 STANDARD FOR HOUSEHOLD GAS COOKING APPLIANCES For use with models DR30GS DR30GFS DR30GIS and DR30GIFS ...

Page 2: ...o change without notice Dacor assumes no liability for changes to specifications 2012 Dacor all rights reserved Product data label view through right side of grate with flashlight Model Identification DR30GIFS NG H SIZE inches TRIM TYPE I Slide in trim No character Freestanding HANDLE TYPE F Flush handle integrated in door No character Handle mounted on outside of door GAS TYPE NG Natural gas LP L...

Page 3: ...rom a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING WARNING NEVER use this appliance as a space heater to heat or warm the room Doing so may result in carbon monoxide poisoning and overheating of the appliance WARNIN...

Page 4: ...f a home appliance as outlined in the literature accompanying it This range is not intended for commercial use DO NOT TOUCH THE SURFACES OF THE OVEN OR COOKTOP DURING OR IMMEDIATELY AFTER USE Do not climb on any part of the appliance Never leave this appliance unattended when in use Do not leave children or pets alone or unattended in the area around the range Do not allow children to play with th...

Page 5: ...E EVENT OF A RANGE TOP GREASE FIRE a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT b NEVER PICK UP A FLAMING PAN you may be burned c DO NOT USE WATER including wet dish cloths or towels a violent steam explosion may result d Use a fire extinguisher...

Page 6: ...ity Product width 29 7 8 75 9 cm NOTE Models DR30GS and DR30GFS are not compatible with a raised vent 35 88 9 cm to 37 94 0 cm 9 22 9 cm Backguard 46 3 4 118 7 cm Overall Dimensions Side View Available Backguards Part Number Description Compatibility AER30GLBG Low profile 1 3 4 inch Standard on models DR30GIS DR30GIFS Optional on models DR30GS DR30GFS AERB30G03 3 Inch Optional on models DR30GS DR3...

Page 7: ... the product data label see inside cover for location The Electrical Supply Requirements provided below are for reference Electrical Circuit Required Total Connected Load 120 Vac 60 Hz 15 Amp 0 5 kW 4 0 Amp Electrical Supply Requirements IMPORTANT The above information is for reference only If the information above differs from the information on the product data label on the appliance use the inf...

Page 8: ...t be sealed Cabinet Layout Note 2 B A Back wall immediately behind range6 Top of finished counter 13 33 0 cm max 4 14 35 6 cm min 4 C Suggested location of utilities3 Note 5 Note 1 A B C 30 minimum 76 2 cm 36 91 4 cm recommended 30 76 2 cm minimum 37 94 0 cm maximum Freestanding Installation Cabinet Cutout Dimensions Models DR30GS DR30GFS DR30GIS and DR30GIFS See cutout dimensions on facing page f...

Page 9: ...ace Notch countertop to width of cabinets 3 4 min 1 9 cm countertop overhang 10 min 25 4 cm to any combustibles above counter both sides 21 1 8 53 7 cm to 24 1 8 61 3 cm 20 7 8 53 0 cm 25 3 4 65 4 cm max Countertop front Rear wall or countertop edge countertop opening 29 1 4 74 3 cm 30 76 2 cm cabinet opening below countertop below countertop Cabinet face Notch countertop overhang to width of cabi...

Page 10: ...bustibles above counter both sides Countertop overhang 1 5 8 4 1 cm max 20 5 8 52 4 cm raised vent opening 27 1 2 69 9 cm Cabinet face Countertop IMPORTANT If optional side panels are not installed cabinet face must be flush with back of control panel Back of control panel DR30GI F S range 3 8 min 1 0 cm space behind raised vent chassis to clear stiffener 3 8 min 1 0 cm flat countertop overhang re...

Page 11: ...s steel cleaner 1 dual burner ring 1 outer dual burner cap 1 inner dual burner cap 3 standard burner caps 2 large 1 small 3 standard burner rings 2 large 1 small 2 standard oven racks 1 GlideRack oven rack Installation Instructions WARNING If the gas or electric service provided does not meet the product specifications do not proceed with the installation Call the selling dealer the gas supplier o...

Page 12: ...ors when attaching to a wood sub floor 1 Determine the location of the range center line and front panel when the range is in its final position based on the Product Dimensions on page 4 and the actual cabinet cutout dimensions used for the installation 2 Determine the required position of the anti tip bracket based on the diagram bottom right Mark the four 4 mounting hole locations on the floor w...

Page 13: ... will support wall installation of the anti tip bracket If you do not contact the base plate or you contact metal stud mounting materials the wall mounting method may not be used and the floor mounting method must be suitable or the wall must be modified so that the base plate is above the notches 4 To install the bracket place it against the wall in the mounting location shown in the diagram uppe...

Page 14: ...tions Door Removal Remove the door to make the range easier to move during the installation process WARNING Do not attempt to disengage the hinge catches with the door removed from the oven The hinge springs could release causing personal injury Do not lift or carry the oven door by the door handle 1 Open the door to its fully opened position 2 Use a flat blade screwdriver to rotate the catch over...

Page 15: ...e fixing the leak and testing the unit Do not use a flame to check for leaks The maximum gas supply pressure to the regulator must never exceed 1 2 pounds per square inch psi or 3 5 kPa The range and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psi 3 5 kPa The range must be isolated...

Page 16: ...e sure that the notch on the bottom of each hinge rests on top of the lower lip of each hinge receptacle before attempting to open the oven door Rotate the hinge locks toward the front of the range immediately after installation of the door 1 Grasp the oven door on opposite sides and hold it at a 15 angle from the front of the oven Slide the hinges into the hinge openings resting the bottom of the...

Page 17: ...nstall dual burner ring on dual burner base Line up indentations on bottom of burner ring with pins on top of burner base STEP 1 Install standard burner rings on standard burner bases Put holes on edge of each ring over the igniter Center tabs on bottom of each ring in hole in center of each base STEP 2 Set outer dual burner cap on dual burner ring Make sure it is centered on top of burner ring ST...

Page 18: ...sure the knobs light when in the HIGH position 6 After testing all the cooktop burners turn them all off 7 Open the oven door Test the oven light by turning on the light switch on the right side of the control panel 8 Turn on the convection fan switch You should hear the convection fan located behind the screen at the back of the oven come on 9 With the oven door open turn the oven control knob to...

Page 19: ... grounded three prong electrical outlet that has been installed by a licensed electrician according to these instructions and in accordance with all applicable electrical codes See pages 5 and 16 Is the backguard installed Has the gas supply inlet pressure been measured to ensure that it does not exceed the maximums stated in these instructions See page 5 Is the range connected to the gas supply a...

Page 20: ...18 Notes ...

Page 21: ...19 Notes ...

Page 22: ...20 Notes ...

Page 23: ......

Page 24: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com ...

Reviews: