background image

3

Product Dimensions

COOKTOP WIDTH (A)

DRT304S

29 7/8” (75.9 cm)

DRT366S

35 7/8” (91.1 cm)

Installation Requirements

 WARNING

• 

Observe all governing codes and ordinances during 

planning and installation. Contact your local building 

department for further information.

• 

To prevent an electric shock hazard, the power sup-

ply must meet the specifications stated below. 

The electrical and gas supply data on this page is for refer-

ence only. If the requirements below do not agree with the 

product data label, use the data on the product data label.

Electrical Requirements

• 

The electrical installation, including minimum supply 

wire size and grounding, must be done in accordance 

with National Electric Code ANSI/NFPA 70 and local 

codes and ordinances. A copy of this standard may be 

obtained from:

 

National Fire Protection Association 

 

1 Batterymarch Park  

 

Quincy, MA 02269-9101

• 

The correct voltage, frequency and amperage must be 

supplied to the electrical outlet according to the product 

data label located on the bottom of the chassis.

• 

The electrical outlet must be installed by a licensed 

electrician.

ELECTRIC CIRCUIT REQUIREMENTS

Circuit Required

Total Connected Load

120 Vac 60 Hz.,  

15 Amp. (3 wire)

1.0 Amp. @ 120 Vac, 60 Hz.

Gas Supply Requirements

• 

Check your local building codes for the proper method 

of installation. In the absence of local codes, this 

appliance should be installed in accordance with the 

National Fuel Gas Code ANSI Z223.1/NFPA 54. The 

gas service must be installed by a qualified profes-

sional

• 

Be certain that the cooktop being installed is correct for 

the gas service being provided (natural gas or LP gas). 

Also, if operating the cooktop at an altitude above 4000 

ft. (1219 m) make sure it is equipped for high altitude 

operation. See the inside cover for more information.

• 

An external manual shut-off valve must be installed 

between the gas inlet and the cooktop for the purpose 

of turning on or shutting off gas to the appliance.

• 

The factory provided regulator shipped with the appli-

ance must be installed in the gas line that runs from the 

gas shut off valve to the cooktop gas inlet. Use only the 

regulator provided. The regulator inlet accommodates 

a 3/4” gas supply line and is also compatible with a 

1/2” house gas supply. The inlet to the cooktop itself is 

equipped with a 3/4” male NPT fitting.

GAS SUPPLY PRESSURE REQUIREMENTS*

Gas Type

Manifold 

Pressure

Minimum Gas 

Supply Pressure

Natural Gas

5” Water Column 6” Water Column

Propane (LP)

10” Water

Column

11” Water Column

* Maximum gas supply pressure for all models is 1/2 p.s.i.

A

4” (10.2 cm)

5/8” min. 

(1.6 cm)

7 3/4”

 (19.7 cm)

Trim:

1/2”

 (1.3 cm)

thick

25 7/8” (65.7 cm)

1 5/8” (4.1 cm) cooking surface 

height (grate level) above 

countertop

3/4” gas inlet, connects to regulator from 

bottom or rear of unit, end is recessed 

2” (5.1 cm) from chassis bottom

28 1/8” (71.4 cm)

Power cord

32” (81.3 cm) long

Product tolerances: ±1/16” (±1.6 mm) unless otherwise 

noted.

SIDE VIEW

Summary of Contents for DRT304

Page 1: ...ion Instructions Distinctive Series Cooktop Models DRT304S DRT366S Part No 106522 Rev E THIS APPLIANCE HAS BEEN TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI Z21 1 STANDARD FOR HOUSEHOLD GAS AP...

Page 2: ...uilding inspector s use 2009 Dacor all rights reserved If You Need Help If you have questions or problems with installation contact your Dacor dealer or the Dacor Customer Service Team For repairs to...

Page 3: ...ANT If you smell gas Do not use or light any appliance Do not touch any electrical switch or use any electri cal devices including the telephone in your building From a neighbor s phone immediately ca...

Page 4: ...anying it This cooktop is not intended for commer cial or laboratory use DO NOT TOUCH THE SURFACES OF THE COOKTOP OR THE SURROUNDING AREAS DURING OR IMMEDIATELY AFTER USE WARNING General Safety Precau...

Page 5: ...should be installed in accordance with the National Fuel Gas Code ANSI Z223 1 NFPA 54 The gas service must be installed by a qualified profes sional Be certain that the cooktop being installed is cor...

Page 6: ...evel The countertop overhang on the sides of the cutout shown on the following pages covers the recessed por tions of the cooktop behind the control panel and cre ates a seamless look for the installa...

Page 7: ...noted Continued on following pages See note 2 2 See Cabinet Countertop Dimensions Top View 3 Not applicable for cabinets more than a horizontal distance of 10 25 4 cm from the edge of the cooktop 1 Ve...

Page 8: ...l are routed through bottom 1 2 1 3 cm countertop overhang 1 thick mounting platform min Countertop Countertop 1 2 1 3 cm countertop overhang 2 5 1 cm 1 2 5 cm E 24 5 8 62 5 cm D D B C L Cooktop Model...

Page 9: ...low to allow for raised vent gas and electrical connections Countertop Countertop 1 2 1 3 cm countertop overhang 2 5 1 cm 1 2 5 cm 15 38 1 cm 24 1 2 62 2 cm D E D F B C L Stiffener Cabinet face Contro...

Page 10: ...DRT366S Knobs standard PN 106575 04 3 4 Knobs SimmerSear PN 106575 05 1 2 10 inch grate PN 700037 none 1 12 inch grate PN 701196 none 2 14 inch grate PN 101524 2 none Standard burner cap small PN 102...

Page 11: ...h the cooktop Knob Installation 1 Attach the SimmerSear burner knobs A as shown below The SimmerSear knobs have a wider space between the large flame icon and the simmer icon than the standard burner...

Page 12: ...indentations on the bottom of the burner ring with the pins on the top of the burner base 2 Set the outer SimmerSear burner cap s on top of the burner ring s Make sure the burner ring is centered on t...

Page 13: ...e power plug is connected to the electrical outlet and that power is turned on at the circuit breaker or fuse box Check to make sure that all burner parts are properly seated If the burner continues t...

Page 14: ...TOR RL FL FR RR B W B FL INDICATOR LIGHT W B W B W B B W W W W Single Point Spark Module Single Point Spark Module Single Point Spark Module Single Point Spark Module 120V 60Hz 0 25A POWER SUPPLY WIRI...

Page 15: ...T FR INDICATOR LIGHT B B W W W B B B RC INDICATOR LIGHT B W RR INDICATOR LIGHT B W RR RC FC FR RL FL B B Single Point Spark Module W W Single Point Spark Module Single Point Spark Module Single Point...

Page 16: ...Dacor 600 Anton Blvd Suite 1000 Costa Mesa CA 92626 Phone 800 793 0093 Fax 626 403 3130 www Dacor com...

Reviews: