2
4
English
Installation
Instruction
s
Installing the Rangetop, cont.
Checking Flame Quality
All burner flames must be visually checked to assess their quality.
CAUTION
If you want measure the flame, take care to avoid burn injuries.
2
3
1
1.
Soft blue flames
—Normal for natural
gas.
2.
Yellow tips on outer cones
—Normal for
LP gas.
3.
Yellow flames
—Abnormal for any gas
operation
.
NOTE
If the burner flame looks like Ex. 3, call for service,
and do not use the rangetop. Ex. 1 or 2 are normal
burner flames.
Installing the Grates
NOTE
For best results and longest life, install the grates as instructed.
The grates occupy specific positions
on the rangetop and should only be used in those positions. (To help with installation, each grate's
position is formed into the bottom of the grate.)
The back of the right-hand grate is notched to help with placement.
When installed properly, the
openings in the grates are centered over the burners.
To correctly position the grates:
1.
Find the notch on the back of the right-hand grate, and carefully lower it until its legs
rest in the
corresponding dimples on the
range
top.
2.