Installation Instructions
Modernist Rangetop
DTT48M876*/DTT36M876*
Part No. 115115 Rev A
Page 1: ...Installation Instructions Modernist Rangetop DTT48M876 DTT36M876 Part No 115115 Rev A...
Page 2: ...cifications 9 What Is In the Box 9 Parts and Tools Needed 10 Installation Requirements 11 In Preparation 11 Overall Rangetop Dimensions 12 Countertop Cutout Dimensions 13 Gas Supply Requirements 17 Sp...
Page 3: ...emove all packaging from the rangetop before connecting it to the electric gas supplies Observe all governing regulations Installation requires basic mechanical skills The installershall ensure proper...
Page 4: ...CustomerAssurance Team Before calling have the rangetop s model serial numbers available see the data label right hand side of the rangetop chassis DacorCustomerAssurance Phone 800 793 0093 x2813 USA...
Page 5: ...s This product must be installed by a licensed plumberorgas fitterqualified orlicensed by the State of Massa chusetts When using ball type gas shut off valves you must use the T handle type Multiple f...
Page 6: ...afety To reduce risk of property damage fire personal injury and death Do not store place use combustible items e g paper plastic fabrics gasoline nearthe range Do not wearloose fitting orhanging garm...
Page 7: ...operpath forthis ground wire Electrical service to the rangetop must conform to local codes in the absence of which it should meet the latest ANSI NFPA No 70 Latest Revision forthe U S orthe Canadian...
Page 8: ...xide poisoning do not use cookware that is substantially largerthan the grate Turn cookware handles away from surface burners and the rangetop front edge Stand back from the range while frying Heat fr...
Page 9: ...te rangetop Porcelain and brass burnercaps are provided to suit customerpreference The brass will discolorwith use however the discoloration does not affect the caps intended function If you need an a...
Page 10: ...onnector in ID x 5 ft Flare union adapter in NPT x in ID Flare union adapter in NPT x in ID 135 degree elbow option 90 degree elbow option Flat blade screwdriver Phillips screwdriver Open end or adjus...
Page 11: ...to meet the specified parameters The rangetop complies with the maximum allowable wood cabinet temperature of194 F 90 C Ensure the wall covering countertops and surrounding cabinets can withstand this...
Page 12: ...12 English Installation Requirements DTT36M876 DTT48M876 36 91 1 cm 48 121 6 cm...
Page 13: ...s Countertop Cutout Dimensions Installed Rangetop side view Cabinet Countertop Dimensions front view Cutout dimensions must be observed Any overage could be create severe problems Cabinet tolerances 1...
Page 14: ...ertop Cutout Dimensions cont Installed Rangetop side view Cabinet Countertop Cutout Dimensions No Downdraft Vent top view Rangetop Model A B C DTT36M876L 36 91 4 cm 35 88 9 cm 16 5 8 42 2 cm DTT48M876...
Page 15: ...connections must be routed through the bottom of the rangetop when installed with a downdraft vent Model A Cutout Width B Hole Offset C Downdraft Vent Cutout Approved Downdraft Vent Models DTT36M876L...
Page 16: ...out Dimensions cont Cabinet Countertop With Downdraft Vent side view Utility Locations and Dimensions rear Dimension DTT36M876L DTT48M876L D 3 1 2 8 9cm 4 10 1cm E 4 11 16 11 9cm 4 11 16 11 9cm F 5 1...
Page 17: ...as inlet to the shut off valve An external manual shut off valve must be installed between the gas inlet and rangetop forturning on off gas to the appliance Have a qualified technician install the con...
Page 18: ...box All gas models are equipped with a powercord with an equipment grounding conductorand a ground ing plug All gas models in the US and Canada require a120 V 60 Hz AC approved electrical service with...
Page 19: ...Supply 1 Shut off the main gas supplyvalve before disconnecting the old rangetop 2 Complete the gas hookup 3 Open the gas valve and relight the burners on any othergas appliances Because hard piping r...
Page 20: ...est performance minimize gas pressure loss by attaching the regulatoras close as possible to the gas inlet 2 Complete the connection by installing a flexible gas line between the pressure regulatorand...
Page 21: ...er cord Ensure the outlet meets all applicable electrical codes see pg 18 2 After installing the rangetop check the gas supply line to verify it was not damaged and remains connected Assembling the Ra...
Page 22: ...Round BurnerHead Caps 1 Orient the burner head so the opening forthe elec trode aligns with the electrode 1 Put the burnerheads on the burnerbases The bottom of the head fits within the burnerbase 2...
Page 23: ...rner rings The ridge around the bottom edge of the cap fits around the top of the ring Verifying BurnerFunction Afterthe cooktop is fully installed and plugged in make sure all burners work properly 1...
Page 24: ...ng the Grates Forbest results and longest life install the grates as instructed The grates occupy specific positions on the rangetop and should only be used in those positions To help with installatio...
Page 25: ...ngetop is properly installed and ready to operate The gas line was properly connected to the rangetop The gas was turned on All connections were checked forleaks The rangetop is properly plugged in to...
Page 26: ...26 English Notes...
Page 27: ...27 English Notes...
Page 28: ...what purpose was the product purchased A Replacement only C New Home B Part of a Remodel D Other 4 What is yourhousehold income A Under 75 000 D 150 000 200 000 B 75 000 100 000 E 200 000 250 000 C 10...
Page 29: ...RANTY PROCESSING DEPT PO BOX 90070 CITY OF INDUSTRY CA 91715 9907 NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES BUSINESS REPLY MAIL FIRST CLASS MAIL CITY OF INDUSTRY CA PERMIT NO 1600 POSTAGE WI...