Page 1-17
s
eCTion
1 - P
roduCT
f
amiliarizaTion
After All’s in Place
Once the unit is in place it must be leveled and secured to prevent any out of balance
possibilities.
A very important part of the installation process is installation of an anti-tip device. Anti-tip
devices have been around for a long time on ranges. The length of the door in relation to the
body of range makes it easy for an individual to tip the unit over if excess weight is applied to
the open door.
The Dacor Built-in Refrigerators have a similar problem, the refrigerator door is longer than the
cabinet is deep. If excess weight is applied on the door, the unit could tip forward.
If the cutout height is very close to the recommended height of 83¾", the cutout itself will
prevent any possible forward tipping. If there is more than one inch clear above the cabinet, a
section of 2x4 lumber must be mounted to the wall above the cabinet. This 2x4 will keep the
back of the cabinet from leaning away from the wall and will help prevent the possibility of
injury or damage from a mishap. The 2x4 is even included with the product.
It is also possible to prevent tipping using a section of pipe strap. Attach the pipe strap to the
wall and the cabinet. This strap will prevent the unit from tipping away from the wall.
1
2
3
Wall Studs
FIGURE 18
FIGURE 19