Sealed System
The cooling system driven by the compressor incorporates a horizontally
mounted evaporator mounted in the top of the freezer compartment and
a vertical condenser coil mounted in the machine compartment. A post
condenser loop (Yoder Loop) is used to minimize cabinet sweating.
Refrigerant flow is from the outlet of the compressor to the condenser. After
the condenser the liquid refrigerant flows through the Post Condenser (PC)
loop around the freezer door opening and back to the machine compartment.
The PC loop empties into a filter/drier and supplies liquid refrigerant to the
capillary tube. The capillary tube is part of the heat exchanger that crosses
into the evaporator compartment and empties into the evaporator coil. From
the evaporator coil the gas returns through the heat exchanger to the inlet of
the compressor.
The filter drier is mounted vertically with the inlet at the top. It is critical to
maintain proper positioning for both effectiveness and noise reduction. When
performing any sealed system service the filter drier must be replaced.