Page 2-19
s
eCTion
2 - T
eChniCal
o
rienTaTion
Cabinet Lighting
The fresh food and freezer door switches are low voltage switches.
The opening and closing of the doors are sensed by the switches and
in turn by the Main Control board. The Main Control board actually
turns on the relay for the compartment lights.
There are at least three freezer lamps with the possibility for four
lamps for a dispenser model. The fresh food section has a total
of six lamps. Two of the fresh food lamps are on the FoodSaver™
assemblies.
If the door is open long enough for the door alarm to activate (10
minutes) the lamps will be turned off. This will help minimize the
temperature impact on the contents of the compartment should a
door be left open.
NOTE
With this many lamps inside of the cabinet, if the relay
contacts were to weld together, the compressor would be hard
pressed to maintain the desired temperature. If the lamps
do not turn off when the door switches are held in the door
closed position, enter the Service Test Mode. All lamps should
be off in the Service Test Mode unless you are specifically
using the Test Mode to turn the lamps on.
The lamp circuits can be energized from the Service Test
Mode. Service Test 13 will energize the fresh food lights while
Service Test 14 will energize the freezer lamps.
•
•