Page 3-5
s
eCTion
3 - s
erviCe
d
iagnosTiCs
Service Test 10 – Close Damper
This test will drive the electronic damper for the fresh
food compartment to the closed position. Tap the Power
Interrupt Button and the damper will move to the closed
position. There is no change in the display while the
damper closes. It takes between 7 and 15 seconds for the
damper to move to the closed position.
Service Test 11 – Defrost Heaters
This test will energize the defrost heaters. If the defrost
safety thermostat is closed the defrost system will draw
approximately 3 amps.
Pressing the Power Interrupt Button while at Service Test
11 will energize the defrost heaters.
When the Power Interrupt Button is tapped the display
will indicate the current evaporator temperature on the
fresh food side of the display.
The temperature should begin to quickly rise when
the heaters are energized. This can be used to quickly
determine if the defrost system is energized.
Service Test 12 – Condenser Fan
This test will energize the condenser fan.
Pressing the Power Interrupt Button will activate the test.
Line voltage should be present at JP13 pin 1.
SERVICE
SERVICE
SERVICE
SERVICE
SERVICE