Page 4-1
s
eCTion
4 - f
ood
s
aver
™ T
esT
m
ode
FoodSaver™ TEST MODE
To perform the built-in diagnostics that test the FoodSaver™ module, both door switches must be
closed. Tape the fresh food compartment door switch closed. With the door switches closed, the
FoodSaver display should be blank.
To enter the FoodSaver test module, press and hold the Citrus and Produce keypads
for five seconds.
The LCD should display –88 and be illuminated.
All keypads should be illuminated.
The fan should be off.
The damper should close
Wait seven seconds, touch the Citrus Keypad.
The fan will begin turning.
If the controller does not sense fan rotation, an F will be displayed.
The heater will energize.
If the control does not sense heater continuity, an H will be displayed.
The damper will open.
The display should be blank yet illuminated unless indicating an F or H.
The Citrus keypad should be illuminated.
Wait seven seconds, touch the Produce Keypad.
The control will test the thermistor circuit.
If the circuit is open, OC will show in the display.
If shorted, CC will show in the display.
The display should be blank yet illuminated unless indicating OC or CC.
The produce keypad should be illuminated.
Touch the Meat Keypad. (Not applicable to upper FoodSaver)
The meat keypad will illuminate.
Touch the Normal Keypad
This will exit the diagnostic mode.
The diagnostic mode will terminate if the refrigerator door switch is opened or if five
minutes passes with no activity.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Section 4 - FoodSaver™ Test Mode