Installation Requirements
Location Requirements
Gas/Electrical Range Hookups (HDPRS/HDERS 30”, 36”, 48”)
Gas/Electrical Service Inlets
•
Existing utilities may be used if compatible with the requirements in this manual. (See building codes for
allowed gas-valve locations.)
•
An external shut-off valve must be installed between the gas inlet and range so its gas supply can be turned
on/off.
•
The valve and the circuit-breaker panel/fuse box must be accessible without moving the range.
•
The gas-supply piping, shut-off valve, and the electrical junction box/receptacle must not interfere with the
placement requirements for the range.
•
The junction box and gas-shut off valve must be located so the range can be pulled out for service without
being disconnected.
GAS-/ELECTRICAL-ACCESS DIMENSIONS
Model
A
B*
C
D*
E**
HDPR30S/HDER30S
3 ¼" (8.3 cm)
27” (68.6 cm)
6 3/4" (17.1 cm)
6 3/4 (17.1 cm)
7/8” (2.2 cm) dia.
HDPR36S/HDER36S
6 3/4" (17.1 cm)
27” (68.6 cm)
12” (30.5 cm)
HDPR48S/HDER48S
4 ¼” (10.8 cm)
27” (68.6 cm)
9” (22.9 cm)
*Measurement with range legs adjusted to their lowest height; **the hole size for the electrical wiring may be increased to 1 1/8” (2.9
cm) by removing the conduit bracket in the bottom of the electrical box.
48” model shown