Installation Requirements

Location Requirements

Gas/Electrical Range Hookups (HDPRS/HDERS 30”, 36”, 48”)

Gas/Electrical Service Inlets

• 

Existing utilities may be used if compatible with the requirements in this manual. (See building codes for 

allowed gas-valve locations.)

• 

An external shut-off valve must be installed between the gas inlet and range so its gas supply can be turned 

on/off.

• 

The valve and the circuit-breaker panel/fuse box must be accessible without moving the range.

• 

The gas-supply piping, shut-off valve, and the electrical junction box/receptacle must not interfere with the 

placement requirements for the range.

• 

The junction box and gas-shut off valve must be located so the range can be pulled out for service without 

being disconnected.

GAS-/ELECTRICAL-ACCESS DIMENSIONS

Model

A

B*

C

D*

E**

HDPR30S/HDER30S

3 ¼" (8.3 cm)

27” (68.6 cm)

6 3/4" (17.1 cm)

6 3/4 (17.1 cm)

7/8” (2.2 cm) dia.

HDPR36S/HDER36S

6 3/4" (17.1 cm)

27” (68.6 cm)

12” (30.5 cm)

HDPR48S/HDER48S

4 ¼” (10.8 cm)

27” (68.6 cm)

9” (22.9 cm)

*Measurement with range legs adjusted to their lowest height; **the hole size for the electrical wiring may be increased to 1 1/8” (2.9 

cm) by removing the conduit bracket in the bottom of the electrical box.

48” model shown

Summary of Contents for HDPR30S

Page 1: ...Installation Instructions Heritage Pro Range HDPR30S HDPR36S HDPR48S HDER30S HDER36S HDER48S Part No 113428 Rev A...

Page 2: ...8S Ranges 9 HDER30S 36S 48S Ranges 10 Included Accessories HDPR30S HDER30S 11 Included Accessories HDPR36S 48S HDER36S 48S 12 Needed Parts and Tools 13 Installation Requirements 14 Pre installation Ch...

Page 3: ...sonal and professional reference Service Technician The wiring diagram is in an envelope attached to the inside of the rangetop DacorCustomerAssurance Phone 833 35 ELITE 833 353 5483 USA Canada Hours...

Page 4: ...d Afterinstalling the anti tip bracket see Installing the Anti Tip Bracket Pg 17 verify properinstallation by carefully tipping the range forward The bracket should keep the range safely in place When...

Page 5: ...nstallershall ensure properconversion Installation of the range must follow local codes or in theirabsence the National Fuel Gas Code ANSI Z223 1 NFPA 54 latest edition In Canada installation must fol...

Page 6: ...Do not use a towel orotherbulky cloth as a pot holder Grease fires Turn off the burner and if needed use a multi purpose dry chemical orfoam extinguisher Oven fires Keep the doorclosed and turn off th...

Page 7: ...u fabricant et aux r glementations locales L installateurdoit assurerune conversion correcte L installation de la cuisini re doit respecterles codes locaux ou en leurabsence le Code national du gaz co...

Page 8: ...ts du four Ne pas utiliserune serviette ou un autre chiffon volumineux comme porte pot Feux de graisse teignez le br leuret si n cessaire utilisez un extincteur poudre usage chimique ou usage multiple...

Page 9: ...9 English Product Specifications HDPR30S 36S 48S Ranges HDPR48S HDPR36S HDPR30S...

Page 10: ...10 English Product Specifications HDER30S 36S 48S Ranges HDER48S HDER36S HDER30S...

Page 11: ...ure Probe 1 Stainless Steel Cleaner SimmerSearBurnerCaps Porcelain 1 Brass 1 Standard Oven Rack 1 Griddle 1 Literature Kit Standard BurnerRings 3 Burner Control Knobs 4 2 standard 2 MAX GRIDDLE Wok Ri...

Page 12: ...Wok Ring 1 SimmerSearBurnerCaps Porcelain 2 Brass 2 Standard Oven Rack 1 Anti Tip Bracket w Screws and Anchors BroilerPan and Grill Standard BurnerRings 4 18 GlideRackTM Oven Rack 2 HDRP HDER 48 only...

Page 13: ...ewdriver Needle Nose Pliers Pipe Joing Compound Flexible Metal Appliance Conduit 1 2 in ID x 5 ft Phillips Screwdriver Open End orAdjustable Wrench Flare Union Adapter3 4 in NPT x 1 2 in ID Nutdriver...

Page 14: ...l adjacent surfaces The range complies with the maximum allowable wood cabinet temperature of194 F 90 C Adjacent wall coverings countertops and cabinets must tolerate such heat to avoid discoloration...

Page 15: ...oduct Dimensions tolerances 1 16 1 6 mm HDPRS HDERS30 29 7 8 75 9 cm HDPRS HDERS36 35 7 8 91 1 cm HDPRS HDERS48 47 7 8 121 6 cm Range Only Installation Range With Downdraft Installation Critical Depth...

Page 16: ...alling an overhead hood see hood specifi cations forminimum required clearances 2 Cabinet countertop depth is at the customer s discretion but cabinet face must not protrude beyond the rearof the fron...

Page 17: ...ing shut off valve and the electrical junction box receptacle must not interfere with the placement requirements forthe range The junction box and gas shut off valve must be located so the range can b...

Page 18: ...pproved gas detectorpermanufacturerspecifications The range must be installed by a plumberorgas fittercertified by the State of Massachusetts A T handle manual gas valve must be installed in the gas s...

Page 19: ...closed loop terminals or open ended spade lugs with upturned ends connect to a junction box or receptacle installed by a licensed electrician Connect the range via electical conduit or power cord Con...

Page 20: ...3 3 tall formodel HDPRS48 HDERS48 APB48D9 9 tall formodel HDPRS48 HDERS48 Installing the Anti tip Bracket and Foot There are two ways to mount the anti tip bracket Floormounting preferred and wall mou...

Page 21: ...e concrete surface 4 Align the bracket and anchorholes then insert and tighten the screws Attaching the Bracket to a Wood Sub Floor 1 Ceramic stone otherhard flooring overwood Drill 4 countersink hole...

Page 22: ...s shown 7 Attach the bracket to the wall as shown with the fourincluded 12 x1 screws ANTI TIP BRACKETPLACEMENT Dim 30 36 48 C 14 1 8 35 9 cm 3 1 2 8 9 cm 1 Using product dimensions on Pg 13 and actual...

Page 23: ...y the handle If using a backguard install it Pg 17 before sliding the range into place 1 On a stable flat surface lay out some sort of padding on which to put the oven doorafteryou remove it 2 Open th...

Page 24: ...ground circuit which may cause electric shock IMPORTANT Do not disconnect wires inside the range s electrical ac cess coverunless instructed to do so Leave sufficient slack in the conduit orpowercord...

Page 25: ...nding screw E and re move the neutral to ground jumperlink D 3 Remove the conduit s strain relief nut J 4 Slide the wires and the end of the strain relief into the hole on the bottom of the range s el...

Page 26: ...2 Afterconnecting the conduit to the range Pg 22 connect the range s white wire to the neutral white supplywire in the junction box 3 Connect the range s black wire to the black L1 power supplywire 4...

Page 27: ...ain relief down through the hole in the box s bottom b Reassemble the strain relief so the tabs are underthe box and the strain relief itself is in the box Installation Instructions Making the Electri...

Page 28: ...G Green ground wire H White wire I L1 wire J Strain relief 4 Wire Cord Connection 5 Insert the end of the cord up through the hole strain relief 6 Attach the powercord s a white neutral wire H to the...

Page 29: ...ructed Do not use a flame to check forleaks The range s gas pressure regulatoris factory set fora specific type of gas To verify that the range is compati ble with the home gas supply check the rating...

Page 30: ...the the anti tip foot is under the anti tip bracket 6 With a level check that the range does not tilt in any direction adjust the legs as needed to level the range 1 Grasping the oven dooron each side...

Page 31: ...and right side burners 30 feature the words MAX GRIDDLE which refers to the maximum heat setting fora burneroverwhich the griddle is placed Exceeding the MAX GRIDDLE heat level may damage the griddle...

Page 32: ...erring so its base fits within the ridge around the burnerhead and rotate the ring until it drops into place 3 Install the burnercap so the ridge on the bottom of the cap fits overthe perimeterof the...

Page 33: ...7 Open the doorto verify that the oven is heating BAKE and the preheating temp appearon the display 8 Touch CANCEL SECURE orCANCEL RIGHT 48 models The oven s heating elements turns off 9 Push turn a...

Page 34: ...re due to improperinstallation of the range F F Was the plastic coating been peeled off the outside of the range F F Were all packaging materials removed from the oven chamber F F Were the leveling le...

Page 35: ...35 English Notes...

Page 36: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com...