25
English
Installation Instructions
Making the Electrical Connection, cont.
Connecting the Conduit to the Range
For instructions on how to connect the power cord, see Pg. 24.
CONDUIT-TO-RANGE CONNECTIONS
Callout
Description
A
L2 terminal
B
Neutral terminal
C
L1 terminal
D
Jumper link
E
Grounding screw
F
Red wire
G
Green wire
H
White wire
I
Black wire
J
Conduit strain-relief nut
K
Conduit
1. Remove the range's electrical-access cover (see left).
2. (4-wire only)
Loosen the grounding screw (E), and re
-
move the neutral-to-ground jumper link (D).
3.
Remove the conduit’s strain-relief nut (J).
4. Slide the wires and the end of the strain relief into the
hole on the bottom of the range’s electrical box.
5.
Before connecting the wires, slide the strain-relief nut
over the wires, then thread and tighten it onto the strain
relief in the box.
6. Connect the white wire (H) to the neutral terminal (B) in
the box.
7. Connect the black wire (I) to the L1 terminal (C).
8.
Connect the red wire (F) to the L2 terminal (A).
9. (4-wire only)
Connect the green wire (G) to the ground
-
ing screw (E).
10.
Re-attach the electrical-access cover.
3-Wire Connection
(if local code allows)
4-Wire Connection