1.
Remove the range’s electrical-access cover.
2. (4-wire only)
Loosen the ground screw, and remove the
neutral-to-ground jumper link.
3.
Remove the electrical box’s conduit bracket.
4.
Remove the strain relief from the power cord.
a. Insert the tabs on each part of the strain relief down
through the hole in the box’s bottom.
b. Reassemble the strain relief so the tabs are under the
box and the strain relief itself is in the box.
Installation Instructions
Making the Electrical Connection, cont.
Connecting a Power Cord to the Range
Do not connect the range’s green wire to the neutral (white) supply wire unless local code allows.
The range does not come with a power cord; purchase the cord separately.
10-50P 3-Prong Plug (left); 14-50P 4-Prong Plug (right)