background image

PLANNING

GUIDE

Web: http://www.Dacor.com

Corporate Phone: 800-793-0093

Specifications are subject to change without notice.

See installation instructions for additional details.

11.15

42” and 48” Wide

Built-In Refrigerators

EF42DBSS, EF42NBSS, EF48DBSS, EF48NBSS, 

IF42DBOL, IF42NBOL, IF48DBOL, IF48NBOL

2/6

Revised

04/22/08

e

lectrical

 r

equirements

The electrical circuit must meet all local codes and ordinances.
Recommended Grounding Method
A 115 Vac, 60 Hz., 15 or 20 Amp fused, grounded electrical supply 

is required. It is recommended that a separate circuit serving only 

your refrigerator be provided. Use an outlet that cannot be turned 

off by a switch. Do not use an extension cord.

IMPORTANT

: If this product is connected to a GFCI (Ground Fault 

Circuit Interrupter) protected outlet, nuisance tripping of the power 

supply may occur, resulting in loss of cooling. Food quality and 

flavor may be affected.

All installations must meet local plumbing code requirements.

◊ 

The water shutoff should be located in the base cabinet on 

◊ 

either side of the refrigerator or some other easily accessible 

area. The right-hand side is recommended. The access hole 

through the cabinet must be within ½” (12.7 mm) of the rear 

wall.

NOTE

: If the water shut off valve is in the back wall behind the 

refrigerator, it must be at an angle so that the tube is not kinked 

when the refrigerator is pushed into its final position.

W

ater

 s

upply

 r

equirements

Water Pressure

A cold water supply with water pressure between 30 and 120 psi 

(207 and 827 kPa) is required to operate the water dispenser and 

ice maker. 

Reverse Osmosis Water Supply

IMPORTANT

: The pressure of the water supply coming out of 

a reverse osmosis system going to the water inlet valve of the 

refrigerator needs to be between 30 and 120 psi (207 and 827 

kPa). If a reverse osmosis water filtration system is connected to 

your cold water supply, the water  pressure to the reverse osmosis 

system needs to be a minimum of 40 to 60 psi (276 to 414 kPa).

Possible water 

line locations

Access hole within 1/2” 

(12.7 mm) of floor and rear wall

1"

(2.54 cm) 

6"

(15.2 cm)

6"

(15.2 cm)

Summary of Contents for IF42 Series

Page 1: ...m must be maintained above the top grille in order for the top grille to be removed 4 10 2 cm 83 2 212 1 cm min 84 4 215 cm max to bottom of solid soffit 24 60 96 cm min 77 196 cm A Width see chart following Revised 04 22 08 1 3 cm 1 2 Model Series Cutout Width A EF42 IF42 41 105 4 cm to 41 106 1 cm EF48 IF48 47 120 7 cm to 47 121 3 cm NOTE Flooring under refrigerator must be at same level as the ...

Page 2: ...e requirements The water shutoff should be located in the base cabinet on either side of the refrigerator or some other easily accessible area The right hand side is recommended The access hole through the cabinet must be within 12 7 mm of the rear wall NOTE If the water shut off valve is in the back wall behind the refrigerator it must be at an angle so that the tube is not kinked when the refrig...

Page 3: ... wall see Door Swing 90 B a c k e r P a n e l O v e r l a y P a n e l Spacer Panel 1 4 6 35 mm 3 4 1 9 cm 1 2 5 cm 1 2 1 3 cm 1 11 4 11 2 1 2 5 cm 1 3 2 cm 1 4 1 3 8 cm 1 2 1 2 Refrigerator Side Trim D o o r Hinge 2 5 cm 3 2 cm 3 8 cm 1 3 cm Cabinetry 3 4 1 9 cm 110 Door Stop Position When the doors are closed the refrigerator will extend beyond the face of the adjacent cabinetry to some degree NO...

Page 4: ...rigerator into place The weight of the overlay panels cannot exceed 50 lbs 23 kg for the refrigerator door 30 lbs 13 5 kg for the freezer door 10 lbs 4 5 kg for the top grille To minimize panel weight you may use 2 5 08 cm spacer strips around the perimeter in place of full sheet solid spacer panels The spacer strips must be set in at least 1 2 54 cm from the top bottom and sides edges of the back...

Page 5: ...mensions shown are actual product dimensions and may not reflect the needed installation dimensions The side panel should be a minimum of 1 27 cm thick to avoid warping If the opening depth is 25 63 5 cm or more you may want to install a support board on rear wall Refrigerator Side Trim 23 1 2 59 69 cm Overlay 16 4 5 mm 8 9 7 mm 16 1 5 mm 8 3 2 mm A Back wall A Back wall Custom Side Panels IF42 IF...

Page 6: ...e side panel should be a minimum of 1 27 cm thick to avoid warping If the opening depth is 25 63 5 cm or more you may want to install a support board on the rear wall Refrigerator Side Trim 24 8 61 3 cm 23 59 7 cm 23 16 60 3 cm 64 4 5 mm 6 35 mm 16 4 7 mm 7 32 5 5 mm 32 10 mm 5 8 15 7 mm Inset Installation Dimensions Measure the distance from point A as shown to the back 1 wall Add 7 32 5 6 mm to ...

Reviews: