background image

3

Installation Specifications

Product Dimensions

36 1/4" *

(921 mm)

34 3/8"

(873 mm)

19 3/8" 

(495 mm)

21 1/4" *

(540 mm)

4" (102 mm)

Chassis height

30 1/4" *

(768 mm)

28 3/8"

(721 mm)

19 3/8" 

(495 mm)

21 1/4" *

(540 mm)

4" (102 mm)

Chassis height

Electrical Specifications

 IMPORTANT

This appliance is provided with electrical connection 

leads in a flexible metal conduit. These leads may be a 

smaller gage than the standard household wiring of the 

dedicated supply circuit, but they are suitable for connec-

tion to these circuits under the jurisdiction of the National 

Electric Code, and/or the local inspection authority.

It is the owner’s responsibility to ensure that a licensed 

• 

electrician performs the installation of the electrical sup-

ply for this appliance. The electrical installation, includ-

ing minimum supply wire size, must comply with the 

National Electric Code ANSI/NFPA 70 (latest revision) 

and local codes and ordinances. A copy of the standard 

may be obtained from:

National Fire Protection Association 

1 Batterymarch Park 

Quincy, Massachusetts 02269-9101
The correct voltage, frequency and amperage must be 

• 

supplied to the appliance from a dedicated, grounded, 

circuit that is protected by a properly sized circuit 

breaker or time-delay fuse. If a time-delay fuse is uti-

lized, fuse both sides of the line (L1 and L2).

The junction box and the remote circuit breaker panel 

• 

or fuse box, must be accessible when the cooktop is in 

place.

Model

Dedicated 

Circuit Required

Total Connected 

Load**

ETT304-1

240 Vac, 60 Hz.  

3 wire* 40 Amp.

6.9 kW  

(29 Amp.)

ETT365-2

240 Vac, 60 Hz.  

3 wire* 40 Amp.

9.1 kW  

(38 Amp.)

MET304

240 Vac, 60 Hz.  

3 wire* 40 Amp.

6.9 kW  

(29 Amp.)

METB365-1

240 Vac, 60 Hz.  

3 wire* 50 Amp.

9.6 kW  

(40 Amp.)

* Two 120 Vac hot (L1 and L2) and one ground (all copper).
** For reference only. See the product data label (on the 

bottom of the unit) for exact specifications. The minimum 

wire size required by the manufacturer is 8 AWG. Local 

codes may require that minimum wire gauge used exceed 

this requirement for the power requirements listed on the 

product data label.

Models ETT304-1, MET304

Models ETT365-2, METB365-1

All tolerances: ±1/16 (±1.6 mm), unless otherwise stated.

* For units with stainless steel trim, 

other units may be up to 1/8” less

Summary of Contents for Millennia ETT304-1

Page 1: ...ons Millennia Electric Cooktop For use with models ETT304 1 ETT365 2 MET304 and METB365 1 Part No 65170 Rev J TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI Z21 1 AND U L 858 STANDARD FOR HOUSEH...

Page 2: ...n If You Need Help If you have questions or problems with installation contact your Dacor dealer or the Dacor Customer Service Team For repairs to Dacor appliances under warranty call the Dacor Distin...

Page 3: ...d these installation instructions completely and care fully before you begin the installation process Leave these installation instructions with the customer Customer Keep these installation instructi...

Page 4: ...en to play with the controls Do not store items of interest to children above or on top of the cooktop Children could be burned or injured while climbing on the appliance Do not tamper with the contro...

Page 5: ...rch Park Quincy Massachusetts 02269 9101 The correct voltage frequency and amperage must be supplied to the appliance from a dedicated grounded circuit that is protected by a properly sized circuit br...

Page 6: ...be avoided Make certain that electrical power meeting the speci fications on page 3 can be provided in the selected location Verify that the electrical location is permitted by local building codes Lo...

Page 7: ...a Raised Vent Installed Countertop Cutout Dimensions With Raised Vent Installed Installation Specifications Dimension Table Installations with Raised Vent Model Configuration A Cooktop Cutout Width B...

Page 8: ...ktop will be connected at the circuit breaker panel or fuse box Feed the appliance conduit into the electrical junction 2 box and attach it using a UL certified strain relief Depending upon local code...

Page 9: ...a separate copper grounding wire No 10 minimum and a clamp with an external grounding screw The grounded cold water pipe must have metal continuity to electrical ground and must not be interrupted by...

Page 10: ...nner one and an outer one To activate the outer element Press the ON OFF key for the left front element and press the 8 number setting Activate the outer element by pressing the outer element key the...

Page 11: ...10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 CANCEL SECURE ON OFF ON OFF ON OFF ON OFF 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Cooktop...

Page 12: ...Dacor Phone 800 793 0093 FAX 626 403 3130 www Dacor com...

Reviews: