background image

PLANNING

GUIDE

3.5

Specifications subject to change without notice.

Phone: (800) 793-0093

www.dacor.com

30 Inch and 36 Inch Wide,

Renaissance

®

 Electric Cooktops

Ett304-1 and Ett365-2

All tolerances: +1/16”, -0,  (+1.6 mm, -0) unless otherwise stated

Document # PG03-002

Revised 10/01/11   Page 2/3

When installing model ETT365-2 and the bottom of the chassis is to be enclosed 

wall to wall, you must install Dacor ventilation duct kit ATD323.

Allow a minimum of 6 inches (15.2 cm) clearance between 

the top of the countertop and any combustible surface 

below, including the upper edge of a drawer below the 

cooktop. Proper under-cabinet clearance is also required 

for the cooktop hold down brackets.

6” (15.2 cm)

min. clearance

to combustible

surfaces

A

6" (15.2 cm) min. 

from mounting surface to 

combustibles below

cooktop chassis

B

min. to combustible,

side wall, both sides

 

Rear

wall

1" min.

19 3/4" min.

(50.2 cm)

6" (15.2 cm)

(2.5 cm)

2 1/4" min.

(5.7 cm)

UNDER CoUNtER CLEARANCE

Model

(A) Minimum Under Counter 

Clearance (Width)

ETT304-1

30 1/2” (77.5 cm)

ETT365-2

36 1/2” (92.7 cm)

Model

(B) Minimum Under Counter 

Clearance (Width)

ETT304-1

28 3/4” (73.0 cm)

ETT365-2

34 3/4” (88.3 cm)

 CoUNtERtoP CUtoUt (WIthoUt RAIsED vENt)

3/4”

7 3/4” X 4 3/8

” ventilation cut-outs in enclosure floor

1 1/2”

1 1/2”

3/4”

toP vIEW vENtILAtIoN CUtoUt

Cooktop cutout in 

top of cabinet

Reviews: