English
1
7
Installation Requirement
s
Gas and Electrical Service
•
See below for the recommended location of the gas inlet and electrical junction box/receptacle.
Existing utilities may be used if they are compatible with this range. Check local building codes
for allowed gas-valve locations.
•
An external manual shut-off valve must be installed between the gas inlet and range so the
range's gas supply can be turned on/off. Installation must allow access to the gas shut-off valve
when the unit is installed and access to the remote circuit-breaker panel/fuse box without
moving the range.
•
The gas-supply piping and shut-off valve, and the electrical junction box/receptacle must be
located so as not to interfere with the range when it is installed.
•
The junction box and gas-shut off valve must be located so the range can be pulled out for
service without being disconnected.
G
E
D
F
Recommended
position for
Gas stub
Recommended
position for
electrical outlet
Model
D
E
F
G
DOP36M94D
8 7/8" (22.5 cm) 6 5/8" (16.8 cm) 11 3/16" (28.4 cm) 24 1/4" (61.6 cm)
DOP48M96D
5 1/2" (13.9 cm) 6 5/8" (16.8 cm)
8 1/8" (20.6 cm) 26 5/8" (67.6 cm)