17
English
Installation Requirements
Gas and Electrical Service
• See below for the recommended location of the gas inlet and electrical junction box/receptacle. Existing
utilities may be used if they are compatible with this range. Check local building codes for allowed gas-
valve locations.
• An external manual shut-off valve must be installed between the gas inlet and range so the range's gas
supply can be turned on/off. Installation must allow access to the gas shut-off valve when the unit is in-
stalled and access to the remote circuit-breaker panel/fuse box without moving the range.
• The gas-supply piping and shut-off valve, and the electrical junction box/receptacle must be located so as
not to interfere with the range when it is installed.
• The junction box and gas-shut off valve must be located so the range can be pulled out for service without
being disconnected.
Model
D
E
F
G
DOP36M86D*
8 7/8" (22.5 cm)
6 5/8" (16.8 cm)
11 3/16" (28.4 cm)
24 1/4" (61.6 cm)
DOP48M86D*
5 1/2" (13.9 cm)
6 5/8" (16.8 cm)
8 1/8" (20.6 cm)
26 5/8" (67.6 cm)