25
English
Installation Instructions
Installing the Flexible Conduit
Remove the conduit connection plate from the rear of the drawer body, and flip it as shown. (Use the 1⅛" hole.)
1. Prepare the conduit cord (Figure 1).
2. Install the conduit cord (Figure 2).
Conduit installations: Insert the strain relief (not included) in the 1⅛"conduit hole, thread the conduit cord
through the body of the strain relief, and fasten the ring, then reinstall the bracket.
Installing a 3-wire Conduit
• Aluminum building wire may be used but must be rated for the correct amperage and voltage.
Connect wires according to Step 4 depending on the number of wires.
• Wire used, location/enclosure of splices, etc., must follow good wiring practices and local
codes.
1. Loosen the three lower screws on the terminal block.
2. Insert the white/neutral bare wire tip through the
bottom-center block opening. (Some models: the wire
inserted through the ground-strap opening into the
bottom-center block opening.)
3. Insert the left and right wire tips into their respective
block openings.
4. Tighten the screws to 35 – 50 in.-lbs.(Any tighter may
damage the wires.)