background image

5

B.  Connecting the Green Appliance Wire to 

the Neutral (White) Supply Wire – Where 

Local Codes Permit 

1.  Connect the green and white appliance 

wires to the neutral (white) supply wire in 

the junction box.

2.  Connect the black appliance wire to the 

black (L1) power supply wire in the junction 

box.

3.  Connect the red appliance wire to the red 

(L2) power supply wire in the junction box.

C.  Connecting the Green Appliance Wire to 

a Grounded Supply Wire or a Grounded 

Cold Water Pipe – Where Local Codes 

Permit.

1.  Separate the green and white appliance 

wires.

2.  Connect the white appliance wire to the 

neutral (white) supply wire in the junction 

box.

3.  Connect the black appliance wire to the 

black (L1) power supply wire in the junction 

box.

4.  Connect the red appliance wire to the red 

(L2) power supply wire in the junction box.

5.  Connect the green appliance wire to a 

grounded supply wire in the junction box or 

to a grounded cold water pipe. 

6.  If connecting to a grounded cold water 

pipe, a separate copper grounding wire 

(No. 10 minimum) must be connected to a 

grounded cold water pipe by means of a 

clamp and then to an external grounding 

connector screw.

Conduit from

appliance

Cable from

power supply

Wire nut

(3 places)

Junction

box

RED
RED

GREEN

WHITE

WHITE

BLACK
BLACK

**Connecting the appliance to a

three-wire power supply

Conduit from

appliance

Cable from

power supply

Wire nut

(4 places)

Junction

box

RED

RED

GREEN

GREEN

WHITE

WHITE

BLACK

BLACK

Separate No. 10 (minimum)

copper grounding wire

Clamp must be

tight on pipe

No. 4

copper wire

Metal

water pipe

Clamps

Bare metal

Meter

Connecting the appliance ground to a grounded junction box wire or grounded cold water pipe

Gas Connection

Before sliding the range into the cabinet, 

connect a flexible gas connector to the gas 

shut-off valve previously installed on the stub 

out. The gas valve must be turned off during 

installation. Connect the flex connector to the 

pipe fitting at the right rear of the range.

WARNINGS:

1.  Do not apply excessive 

pressure when tightening gas 

connections and fittings.

2.  Do not use teflon tape or 

plumber’s putty on gas flex 

line connections.

3.  Turn all cooktop control valves 

to the “OFF” position. Turn 

on gas supply and check all 

lines and connections for 

leaks using a soap and water 

solution. Do not use a flame to 

check for leaks. After verifying 

that there are no gas leaks, 

turn off the gas supply to 

the range by turning the gas 

shut-off valve to the “OFF” 

position.

4.  For LP installations, the LP 

gas tank must have its own 

high pressure regulator. This 

is in addition to the pressure 

regulator provided with the 

range.

5.  The maximum gas supply 

pressure to the regulator must 

never exceed 1/2 pound per 

square inch.

NOTE:

The gas pressure regulator is 

pre-set at the factory for the 

type of gas intended for use 

with the appliance. Verify that 

the appliance is compatible with 

the type of gas available by 

checking the data plate located 

behind the inlet air cooling grill. 

Ranges intended for use with LP 

gases will have “LP” as a part 

of the model number. Consult 

your dealer if the range is not 

compatible with your gas supply.
Installing the Range

Measure from the floor to the countertop and 

adjust the leveling legs as required to position 

the top frame at the desired height, based on 

the cabinet and countertop installation. Carefully 

slide the range into position in the cutout. The 

left rear leveling leg should engage the anti-tip 

bracket.)

When the range is to be installed as a “slide-in, 

self rimming” (with the range top overhanging 

the countertop cutout), measure from the floor 

to the countertop. Adjust the leveling legs to 

position the bottom edge of the range top 

frame approximately 1/8” above the level of the 

countertop. This will allow the range to slide 

over the countertop. Carefully slide the range 

into position in the cutout. The left rear leveling 

leg should engage the anti-tip bracket. To lower 

the range onto the countertop, turn the leveling 

legs counterclockwise. Lower the range until 

the bottom of the range top just contacts the 

countertop. Do not allow the full weight of the 

range to hang on the counter.

Installing the Burner Components

Remove the brass burner rings, porcelain burner 

caps, and porcelain gates from their shipping 

packages. Place each burner ring onto its 

corresponding burner base, being certain that 

the five alignment tabs slide into the matching 

notches in the base. Set each porcelain burner 

cap on top of its corresponding burner ring. 

Place oven exhaust cover over the opening in 

the center of the top frame. Place each grate 

onto the top frame, being certain that the rubber 

feet are positioned in the locating dimples.

WARNING:

Never attempt to operate the 

cooktop section of the range with 

any of the burner rings, burner 

caps or grates removed.

NOTE:

Prior to operating the cooktop or 

oven sections of the range, please 

read the accompanying Use and 

Care Manual carefully. Important 

safety, service and warranty 

information is contained within 

this manual.

Re-installing the Oven Door(s)

Grasp the oven door on opposite sides and 

lift it until the door hinges are aligned with the 

openings in the oven frame. Holding the door at 

about a 30˚ angle from the horizontal, slide the 

hinges into the openings until the bottom hinge 

arms drop fully into the hinge receptacles. Lower 

the door to the fully opened position, and then 

rotate the two hinge catches toward the oven. 

Open and close the door completely to ensure 

that it is properly installed. Peel off the protective 

layer of plastic that covers the door panel.

Summary of Contents for Preference RSD30

Page 1: ...ge 2 STEP 5 Cabinet and countertop preparation Page 2 3 STEP 6 Overall dimensions Page 3 4 STEP 7 Installing the anti tip bracket Page 4 STEP 8 Removing the oven door Page 4 STEP 9 Removing the kick p...

Page 2: ...must not be used in combination with surface countertop ventilation systems The use of an overhead hood or Dacor Raised Vent is recommended for ventilation 8 This appliance must be installed with the...

Page 3: ...by a qualified electrician 3 If the appliance is connected to a 120 208 volt power supply preheat times and cavity temperature recovery times will be increased slightly Gas and Electrical Rough In Loc...

Page 4: ...ometric View RSE Shown Utilities may be located 1 In the lower left corner of the adjacent right cabinet Recommended 2 Alternate location in the lower right corner behind the range Note Some building...

Page 5: ...nce require an anti tip device Before installing the range you must locate and secure the anti tip bracket to the floor When the range is slid into position in the cutout the left rear leveling leg sl...

Page 6: ...und per square inch NOTE The gas pressure regulator is pre set at the factory for the type of gas intended for use with the appliance Verify that the appliance is compatible with the type of gas avail...

Page 7: ...be steady and quiet It will also have a sharp blue inner cone that will vary in length proportional to the burner size Verify Proper Operation for Electric Ranges RSE and MRE Before beginning the test...