background image

Verifying the Package Contents

If any item is missing or damaged, please 

contact your dealer immediately. Do not install a 

damaged or incomplete appliance.

All Ranges

•  Use & Care Manual

•  Anti-tip Bracket

•  Broiler Grill and Pan

•  Oven Racks

Ranges w/ Gas Top Burners & MRES30 Only

•  Ignitor Cleaning Kit

•  Burner Ring Set

•  Grate/Burner Cap Pack

•  Simmer Plate

Electric Ranges Only

•  Razor Blade Scraper

•  Cooktop Cleaning Cream

Gas Supply Requirements

Check your local building codes for the proper 

method of installation. In the absence of local 

codes, this appliance should be installed in 

accordance with the National Fuel Gas Code 

ANSI Z223.1. Be certain that the appliance 

being installed is correct for the gas service 

being provided.

wARNING:

This appliance must be installed 

by a licensed plumber or gas 

fitter when installed within the 

Commonwealth of Massachusetts.

dacor

Model 

Number

dedicated 

electrical

circuit required

Total

connected

load

Gas type

Manifold

pressure

Min. gas

supply

pressure

RSD30

120/240VAC,

60Hz, 30A

5.4kW (23.3A)

Natural

4” water

column

5” water

column

RSD30LP

Liquid Propane

10” water

column

11” water

column

RSE30

120/240VAC,

4-wire, 60Hz, 50A

11.1kW (46.7A)

N/A

N/A

N/A

MRES30

10.3kW (43.7A)

N/A

N/A

N/A

Gas and Electrical Requirements

Electrical Power Supply 

Requirements

It is the owner’s responsibility to ensure that 

the electrical connection of this appliance 

is performed by a qualified electrician. The 

electrical installation, including minimum supply 

wire size and grounding, must be in accordance 

with the National Electric Code ANSI/NFPA 70-

2002* (or latest revision) and local codes and 

ordinances. 

*A copy of this standard may be obtained from:

National Fire Protection Association

1 Batterymarch Park

Quincy, Massachusetts 02269-9101

The correct voltage, frequency, and amperage 

must be supplied to the appliance from a 

separate, grounded, circuit that is protected by a 

properly sized circuit breaker or time delay fuse. 

Refer to the data plate, and/or the Table above, 

for gas supply requirements.

wARNING:

If the gas or electric service 

provided does not meet the 

product specifications, do not 

proceed with the installation. 

Call the selling dealer, the gas 

supplier, or a licensed electrician.

NOTES:

1.  The power supply must 

be properly polarized. 

Reverse polarity will result in 

continuous sparking of the 

electrodes, even after flame 

ignition.

2.  If there is any doubt as to 

whether the power supply 

is properly polarized or 

grounded, have it checked by 

a qualified electrician.

3.  If the appliance is connected 

to a 120/208 volt power supply, 

preheat times and cavity 

temperature recovery times 

will be increased slightly.

Gas and Electrical Rough-In 

Locations

NOTE:

The shaded areas shown in 

the illustrations, denotes the 

location of the gas stub and the 

electrical junction box/receptacle. 

These are suggested locations. 

For replacement purposes, the 

location of the existing utilities 

may be utilized provided that they 

do not interfere with the sides 

or rear of the range. Verify that 

local building codes will permit 

installing the gas valve behind the 

range.

A manual shut off valve must be installed in the 

gas piping, external to the appliance, for the 

purpose of turning on or shutting off gas to the 

appliance. Plan the location of the range and the 

gas supply to allow access to the valve when 

the unit is installed and in operation. Access to 

the remote circuit breaker panel/fuse box, with 

the range in place and operating, must also be 

allowed for in the installation. Any openings in 

the wall behind the appliance and in the floor 

under the appliance must be sealed. 

Both the gas supply piping and shut-off valve, 

and the electrical junction box/receptacle must 

be located so they do not interfere with the 

range when it is installed and under operation. 

In addition, the junction box must be located 

so the range can be removed for service when 

the conduit supplied with the unit is attached to 

the junction box. Do not lengthen the conduit or 

wiring provided with the range. 

All dimensions shown are based on standard 

American cabinets 36 inches (914mm) high 

at the finished countertop by 24 inches 

(610mm) deep, with a 25 inch (635mm) overall 

countertop depth. When installing the range 

into nonstandard cabinets, minimum clearances 

shown in the diagrams must be maintained.

Carefully check the location where the range is 

to be installed. For best performance, the range 

should be placed away from drafts that may be 

caused by doors, windows and HVAC outlets.

Cabinet and Countertop Preparation

NOTES:

1.  If cabinet storage space is to 

be provided directly above 

the range, the risk of personal 

injury may be reduced by 

installing a ventilating hood 

that projects horizontally a 

minimum of 5 inches (127mm) 

beyond the face of the 

cabinets. 

2.   The range may be installed 

flush to the rear wall. we 

recommend installing a non-

combustible material on the 

rear wall above the range 

and up to the vent hood. It 

is not necessary to install 

non-combustible materials 

behind the range below the 

countertop height.  

3.   The minimum distance from 

the sides of the range above 

the countertop to combustible 

side walls must be at least 6 

inches (152mm).

The above electrical specifications are for reference only. See the range data plate for exact 

specifications. See page 1 for location.

Summary of Contents for Preference RSE30

Page 1: ...eparation Page 2 3 STEP 6 Overall dimensions Page 3 4 STEP 7 Installing the anti tip bracket Page 4 STEP 8 Removing the oven door Page 4 STEP 9 Removing the kick panel Page 4 STEP 11 Electrical connec...

Page 2: ...r to Electrical Requirements 11 Install or locate this appliance only in accordance with these installation instructions 12 Use this appliance only for its intended use as described in this manual Do...

Page 3: ...ower supply preheat times and cavity temperature recovery times will be increased slightly Gas and Electrical Rough In Locations NOTE The shaded areas shown in the illustrations denotes the location o...

Page 4: ...ic View RSE30 Shown Utilities may be located 1 In the lower left corner of the adjacent right cabinet Recommended 2 Alternate location in the lower right corner behind the range Note Some building dep...

Page 5: ...nti Tip Bracket WARNING This appliance require an anti tip device Before installing the range you must locate and secure the anti tip bracket to the floor When the range is slid into position in the c...

Page 6: ...es to the OFF position Turn on gas supply and check all lines and connections for gas leaks using a soap and water solution Do not use a flame to check for leaks After verifying that there are no gas...

Page 7: ...conds the element should be fully energized and glowing red Verify that the residual heat indicator light comes on in conjunction with the proper element within approximately 30 seconds Return the kno...

Page 8: ...his book are the copyright property of Distinctive Appliances Inc Neither this book nor any information or images contained herein may be copied or used in whole or in part without the express written...