PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
9.3
Remote Blowers
REMP3, REMP16
1/3
Revised
01/30/09
REMP3 ovERALL DIMENsIoNs
(Top & Side Views)
17 3/8" (441mm)
19" (483mm)
24 1/4"
(616mm)
3 5/8"
(92mm)
2 1/8"
(92mm)
9 1/4"
(235mm)
Mounting
Flange
25 1/2"
(648mm)
7 1/2"
(191mm)
4"
(102mm)
9 1/2" (241mm)
Discharge
Cutout Location
11”W x 12 5/8”H
(279mm X 321mm)
Intake Collar
Power Supply
Conduit Hole
C
L
C
L
C
L
C
L
5 13/16"
(148mm)
8" Nom.
(203mm)
7 15/16"
(202mm)
Discharge
Intake Collar
REMP16 ovERALL DIMENsIoNs
(Top & Side Views)
26" (660mm)
32 1/4"
(819mm)
3 5/8"
(92mm)
2 1/8"
(54mm)
12 1/4"
(311mm)
Mounting
Flange
33 1/2"
(851mm)
9 1/2"
(241mm)
4"
(102mm)
13 1/8"
(333mm)
Discharge
Cutout Location
13”W X 16 5/8”H
(330mm X 422mm)
Intake Collar
Power Supply
Conduit
Location
C
L
C
L
C
L
C
L
24 1/4" (616mm)
9 9/16"
(243mm)
10" Nom.
(254mm)
11 1/2"
(292mm)
Discharge
Intake Collar
WARNING
1.
Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
2.
This appliance must be installed in accordance with the
accompanying installation instructions.
+/- 1/16” (+/- 1.6mm) unless otherwise stated
Model No.
Electrical Supply
Requirments
Maximum Duct
Length
Total Connected
Load
Blower Rating*
Approximate
Shipping Weight
Finish
REMP3
Refer to raised
vent or hood
specifications
Refer to raised
vent or hood
specifications
120 Vac, 3.8 Amp
600 CFM (nominal)
620.5 CFM (actual)
35 lbs.
Galvanized
(may be painted)
REMP16
120 Vac, 2.7 Amp
1000 CFM (nominal)
994.8 CFM (actual)
55 lbs.
* At 0" static pressure