background image

PLANNING

GUIDE

Web: http://www.Dacor.com

Corporate Phone: 800-793-0093

Specifications are subject to change without notice.

See installation instructions for additional details.

9.3

Remote Blowers

REMP3, REMP16

1/3

Revised

01/30/09

REMP3 ovERALL DIMENsIoNs

(Top & Side Views)

17 3/8" (441mm)

19" (483mm)

24 1/4"

(616mm)

3 5/8"

(92mm)

2 1/8"

(92mm)

9 1/4"

(235mm)

Mounting 

Flange 

25 1/2" 

(648mm) 

7 1/2"

(191mm)

4"

(102mm)

9 1/2" (241mm)

Discharge 

Cutout Location

11”W x 12 5/8”H

(279mm X 321mm)

Intake Collar

Power Supply

Conduit Hole

5 13/16" 

(148mm) 

8" Nom.

(203mm)

7 15/16"

(202mm)

Discharge 

Intake Collar 

REMP16 ovERALL DIMENsIoNs

(Top & Side Views)

26" (660mm)

32 1/4"

(819mm)

3 5/8"

(92mm)

2 1/8"

(54mm)

12 1/4"

(311mm)

Mounting 

Flange 

33 1/2" 

(851mm) 

9 1/2"

(241mm)

4"

(102mm)

13 1/8" 

(333mm)

Discharge 

Cutout Location

13”W X 16 5/8”H

(330mm X 422mm)

Intake Collar

Power Supply 

Conduit 

Location 

24 1/4" (616mm)

9 9/16" 

(243mm) 

10" Nom.

(254mm)

11 1/2" 

(292mm) 

Discharge 

Intake Collar 

 WARNING

1.  

Observe all governing codes and ordinances during planning 

and installation.  Contact your local building department for 

further information.

2.

 

This appliance must be installed in accordance with the 

accompanying installation instructions.

+/- 1/16” (+/- 1.6mm) unless otherwise stated

Model No.

Electrical Supply 

Requirments

Maximum Duct 

Length

Total Connected 

Load

Blower Rating*

Approximate 

Shipping Weight

Finish

REMP3

Refer to raised

 vent or hood

specifications

Refer to raised

 vent or hood

specifications

120 Vac, 3.8 Amp

600 CFM (nominal)
620.5 CFM (actual)

35 lbs.

Galvanized

(may be painted)

REMP16

120 Vac, 2.7 Amp

1000 CFM (nominal)

994.8 CFM (actual)

55 lbs.

 * At 0" static pressure

Reviews: