Important Safety Instructions

• 

Do not install or operate this unit if it has been dam-

aged, dropped, has damaged electrical wiring or 

is not working properly. If you receive a damaged 

product, immediately contact the dealer or builder.

• 

Install or locate this appliance only in accordance 

with these installation instructions and the Dacor 

hood or downdraft vent installation instructions. 

Improper installation, adjustment, alteration, service 

or maintenance can cause serious personal injury or 

property damage.

• 

Before installing or servicing the blower, make sure 

that power to the wiring is turned off at the circuit 

breaker or fuse box. Make sure that the service 

panel is locked or tagged to prevent power from 

being switched on accidently.

• 

A minimum of two people are required to safely 

install this appliance.

• 

The installer must show the customer the location 

of the fuse or circuit breaker panel so that the cus-

tomer knows where and how to turn the power off.

• 

To reduce the risk of electric shock or fire, the total 

combined current draw of the in-line blower and the 

hood or downdraft vent must not exceed the maxi-

Product Specifications

 WARNING

General Safety Precautions

To reduce the risk of fire, electric shock, serious injury or death when using this blower, follow basic safety precautions, 

including the following:

mum rated input current of the hood or downdraft 

vent.

• 

Never allow the filters or vent openings on the hood 

or downdraft vent to become blocked or clogged. 

Do not allow foreign objects, such as cigarettes or 

napkins, to be sucked into the vent holes.

• 

Tape all duct joints securely to prevent combus-

tion by-products, smoke or odors from entering the 

home. Doing so will also improve system efficiency.

• 

Do not route electrical wiring near hot surfaces.

• 

Do not ground the appliance with the neutral (white) 

house supply wire. A separate ground wire must be 

utilized.

• 

To prevent a damaged or non-functional system, 

complete electrical connections properly. Follow 

the wiring diagrams carefully in the hood or in-line 

blower installation instructions to ensure a proper 

installation. After installation or service, make sure 

that all blower wires are tightly connected to their 

respective terminals.

 WARNING

Electrical Supply Requirements

• 

The power for this blower is supplied via 1/2” 3-wire 

wiring/conduit (not included) by an approved Dacor 

hood or downdraft vent. The wiring/conduit is installed 

between the hood or downdraft vent and the blower 

and shall be terminated on each end by a 1/2” UL certi-

fied strain relief. The power is turned on and off by the 

power switch on the approved ventilation device.

• 

The correct voltage, frequency and amperage must be 

supplied to the hood or downdraft vent and the blower 

from a grounded, single phase circuit that is protected 

by a properly sized circuit breaker or time-delay fuse. 

The circuit must have the capacity to supply the com-

bined power requirements for the hood or downdraft 

vent and the in-line blower. See the installation instruc-

tions for the hood or downdraft vent to determine total 

power requirements in combination with the blower 

electrical specifications.

Model*

Power Requirements** Blower Rating***

REMP3 120 Vac, 60 Hz., 3.8 Amp.

600 CFM

REMP16 120 Vac, 60 Hz., 2.7 Amp.

1000 CFM

*  All models are thermally protected. 

**   In addition to the hood or downdraft vent. 

***  Nominal rating at 0 inches static pressure. See  

 

 

Technical Data

 section for actual ratings.

• 

The above specifications are for reference only, See 

the data label on the blower for exact specifications. 

If the above specifications vary from the label on the 

blower, use the data on the blower label.

• 

It is the owner’s responsibility to ensure that the power 

supply is installed by a licensed electrician. The electri-

cal installation must comply with the latest revision of 

the National Electric Code ANSI/NFPA 70 (latest revi-

sion) and local codes and ordinances. A copy of the 

specification may be obtained from: 

National Fire Protection Association 

1 Batterymarch Park 

Quincy, Massachusetts 02269-9101

Summary of Contents for REMP3

Page 1: ...Rev J Suitable for use in a household cooking area Suitable for use with solid state controls To complete this blower a Dacor hood assembly or Dacor downdraft vent must be purchased separately See the...

Page 2: ...fully before you begin the installation process Leave these installation instructions with the customer Customer Keep these installation instructions for future reference and the local electrical insp...

Page 3: ...S OBSERVE THE FOLLOWING a Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer b Before servicing or cleaning unit switch power off at service p...

Page 4: ...n functional system complete electrical connections properly Follow the wiring diagrams carefully in the hood or in line blower installation instructions to ensure a proper installation After installa...

Page 5: ...C L C L C L C L 26 66 0 cm 32 1 4 81 9 cm 3 5 8 9 2 cm 12 1 4 31 1 cm Mounting flange 33 1 2 85 1 cm 9 1 2 24 1 cm Discharge Intake collar Power supply conduit location C L C L C L C L 24 1 4 61 6 cm...

Page 6: ...lated snow if applicable On hori zontally mounted units shield the exhaust if more than 3 8 cm of snow may accumulate on the roof Avoid installing the blower in a location where the exhaust could be e...

Page 7: ...of Curb for flat roofs Roof curb Blower exhaust Prevailing wind 33 1 2 85 1 cm 2 5 1 cm 26 66 0 cm 30 1 2 77 6 cm 6 15 2 cm 2 5 1 cm REMP16 Roof Curb 25 1 2 64 8 cm 2 5 1 cm 19 48 3 cm 23 59 1 cm 6 15...

Page 8: ...4 and meet local codes and ordinances Consult the hood or downdraft vent installation instruc tions for additional part requirements Installation 1 Before installing the blower unpack the unit and ch...

Page 9: ...to place 8 Check the wires from the blower wiring harness to make sure that they are firmly attached to the terminal according to Figure 10 Reconnect any wires that are loose Make sure all terminal sc...

Page 10: ...MP16 1000 CFM 994 8 CFM Airflow CFM Cubic feet minute Static pressure inches of water 0 1 0 2 0 3 0 4 0 5 0 100 200 300 400 500 600 700 REMP3 Blower Performance Airflow CFM Cubic feet minute Static pr...