 WARNING

• 

If the electrical service provided does not meet the 

power requirements for the hood/downdraft vent and 

the blower combined, do not continue with the instal-

lation. Contact a licensed electrician to correct the 

situation before continuing.

• 

Failure to connect the wiring as specified may result 

in an electric shock hazard and/or improper blower 

operation.

• 

To avoid the risk of fire or electric shock, turn off 

power at the circuit breaker panel or fuse box before 

connecting the blower to the power source.

• 

The blower assembly is heavy. Do not attempt to lift 

or move it without assistance.

Parts List

Verify Package Contents

• 

2 1/2” (6.4 cm) wood mounting screws (8)

• 

Blower assembly

Parts Required

• 

3 conductor wiring/conduit with UL certified strain relief 

on each end (length is determined by remote blower 

location).

• 

If the blower will be mounted to a surface other than 

wood, fasteners designed for the material the unit will 

be mounted to must be provided. The fasteners must 

be capable of supporting the weight of the blower (see 

Weight Table

 on page 4) and meet local codes and 

ordinances.. 

• 

Consult the hood or downdraft vent installation instruc-

tions for additional part requirements.

Installation

1.  Before installing the blower, unpack the unit and check 

for physical damage to the motor and blower assembly. 

To do so, reach in through the intake collar and spin 

the fan blades slowly. They should spin freely and qui-

etly without vibration. 

2.  Remove the blower’s top cover by removing the screws 

around the edge that hold it in place.

3.  Apply sealant between the blower and the mounting 

surface where the flange around the edge of the blower 

will rest.

4.  With assistance, pick up the blower assembly and cen-

ter it on the mounting surface inserting the intake collar 

into the cutout.

5.  While holding the blower in place, fasten it to the 

mounting surface with eight (8) mounting screws. The 

mounting holes are located inside the blower assembly 

chassis near the sides.

6.  Install the duct work according to the installation 

instructions for the hood or downdraft vent. Support the 

duct weight as necessary to ensure properly sealed 

joints.

Fan 

blades

Bottom of blower

Intake 

collar

Figure 6

Figure 7

Sealant 

Roof

Air

exhaust

Sealant 

Blower

Round duct

Flange 

Figure 8

45° Adjustable 

elbow

Installation Instructions

Summary of Contents for REMP3

Page 1: ...Rev J Suitable for use in a household cooking area Suitable for use with solid state controls To complete this blower a Dacor hood assembly or Dacor downdraft vent must be purchased separately See the...

Page 2: ...fully before you begin the installation process Leave these installation instructions with the customer Customer Keep these installation instructions for future reference and the local electrical insp...

Page 3: ...S OBSERVE THE FOLLOWING a Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer b Before servicing or cleaning unit switch power off at service p...

Page 4: ...n functional system complete electrical connections properly Follow the wiring diagrams carefully in the hood or in line blower installation instructions to ensure a proper installation After installa...

Page 5: ...C L C L C L C L 26 66 0 cm 32 1 4 81 9 cm 3 5 8 9 2 cm 12 1 4 31 1 cm Mounting flange 33 1 2 85 1 cm 9 1 2 24 1 cm Discharge Intake collar Power supply conduit location C L C L C L C L 24 1 4 61 6 cm...

Page 6: ...lated snow if applicable On hori zontally mounted units shield the exhaust if more than 3 8 cm of snow may accumulate on the roof Avoid installing the blower in a location where the exhaust could be e...

Page 7: ...of Curb for flat roofs Roof curb Blower exhaust Prevailing wind 33 1 2 85 1 cm 2 5 1 cm 26 66 0 cm 30 1 2 77 6 cm 6 15 2 cm 2 5 1 cm REMP16 Roof Curb 25 1 2 64 8 cm 2 5 1 cm 19 48 3 cm 23 59 1 cm 6 15...

Page 8: ...4 and meet local codes and ordinances Consult the hood or downdraft vent installation instruc tions for additional part requirements Installation 1 Before installing the blower unpack the unit and ch...

Page 9: ...to place 8 Check the wires from the blower wiring harness to make sure that they are firmly attached to the terminal according to Figure 10 Reconnect any wires that are loose Make sure all terminal sc...

Page 10: ...MP16 1000 CFM 994 8 CFM Airflow CFM Cubic feet minute Static pressure inches of water 0 1 0 2 0 3 0 4 0 5 0 100 200 300 400 500 600 700 REMP3 Blower Performance Airflow CFM Cubic feet minute Static pr...

Page 11: ......

Page 12: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com...

Reviews: