background image

PLANNING

GUIDE

www.Dacor.com      Phone: (800) 793-0093  

Specifications subject to change without notice.

Install all appliances according to accompanying installation instructions.

8.7

RV30, RV36, RV46

26 3/4"

(679 mm)

1/2” (13 mm)

thick stiffener

across back

4 5/8" (117 mm)

9 7/8” (251 mm)

with CABP3

blower installed

Vent shown

in raised

position

Product 

data label 

2 5/16"

(59 mm)

9/16"

(14 mm)

3 1/8"

(79 mm)

2"

(51 mm)

 B

 A

Adjustable

anchor legs

1 13/16"

(46 mm)

1 15/16"

(49 mm)

3/16"

(5 mm)

Top cap with 

vent down

7" (178 mm)

7 1/2" (191 mm)

Front View

15/16" (24 mm)

28"

(711 mm)

to

34"

(864 mm)

Model

Number

A - Top Cap

Width

B - Chassis

Width

RV30

30” (762 mm)

27 3/8” (695 mm)

RV36

36” (914 mm)

33 3/8” (848 mm)

RV46

46” (1168 mm)

43 3/8” (1102 mm)

All tolerances: +1/16”, -0,  (+1.6 mm, -0) unless otherwise stated

NOTES:
Install these raised vents only with approved Dacor 

1. 

cooktops. See the planning guide for the particular 

appliance for proper applications and cutout information.

This appliance must be install in conjunction with a 

2. 

single Dacor approved cabinet, remote or in-line blower. 

See following pages for approved blowers. For detailed 

information on the remote  and in-line blowers,  

refer to the blower’s installation instructions.

Document # PG08-003

Revised 03/29/10   Page 1/7

 WArNINg

Observe all governing codes and ordinances 

• 

during planning and installation. Contact your 

local building department for further information.
This appliance must be installed in accordance 

• 

with the accompanying installation instructions.

30”, 36”, 46” Wide,

Raised Vent

Summary of Contents for RV30

Page 1: ...3 8 848 mm RV46 46 1168 mm 43 3 8 1102 mm All tolerances 1 16 0 1 6 mm 0 unless otherwise stated NOTES Install these raised vents only with approved Dacor 1 cooktops See the planning guide for the pa...

Page 2: ...conduit parallel to the duct work and connect it to the remote blower and raised vent on the ends There are two 7 8 access holes in the bottom of the raised vent for connecting the wiring to the blowe...

Page 3: ...o remove for access to the cooktop vent and utilities For installation with gas cooktops a 90 degree elbow must be connected to the cooktop gas inlet see diagram below to avoid interference with the r...

Page 4: ...t with in line Blower Duct Work Under Floor wall Exhaust ILHSF series in line blower 3 1 4 X 10 to round transition Duct work Duct work Outside wall Cooktop Wall cap on outside wall Raised vent Raised...

Page 5: ...ack draft never decrease the duct size over the run Do not rely on duct tape alone to seal duct joints Fasten all connections with sheet metal screws and tape all joints with certified silver tape or...

Page 6: ...ting location Bottom Exhaust Location 3 1 4 X 10 C L C L C L 1 7 8 48 mm 1 7 8 48 mm Front View Bottom View 14 3 8 365 mm Back of unit lines up with back of cutout RV 8 3 8 213 mm from back of RV cuto...

Page 7: ...e equivalent length of each 90 elbow is 15 feet The equivalent length of 45 elbow is 2 feet The equivalent length of the transition is 4 feet The total equivalent length of the above components is 15...