Set Max Speed Open:

This setting affects the maximum speed reached while opening. Ranging from 1 to 
21, the lower number will result in a lower speed. The system is designed to handle 
a large range of door sizes and weights, but it should NOT be assumed that your 
door will move at the fastest setting allowed in a safe manner. It is highly 
recommended that upon initial installation, your door be set to a slower speed 
before testing at higher speeds to avoid possible damage. The default settings 
should be a safe speed to begin testing. Increment the values in small amounts 
and test the motion if you choose the increase the speeds. Keep in mind that 
speeds will affect the Opening Trip Level discussed earlier.

Set Max Speed Close:

This setting affects the maximum speed while closing. Ranging from 1 to 21, the 
lower number will be a lower speed. 

Set Direction:

On the Dado Standard Touch Panel, there are two smaller areas towards the 
lower half of the panel that have graphic indicators marked < and >.

On the Dado Door Touch Screen, pressing and holding the < arrow will move the 
door in one direction, and pressing > will move in the opposite direction while the 
arrows are pressed. Due to the fact that there are numerous ways a system can 
be set up, these arrows may not always reflect the direction that the door is 
actually moving in. For the sake of having these arrows move the door in the same 
direction as they are pointing, the Set Direction parameter allows the direction of 
the actual effect of the arrow buttons to be reversed.

If your arrows are moving the door in reverse from how you want to operate the 
door, use the GREEN BUTTON to move the cursor to the Touch Panel you want to  
change the direction(A or B Touch Screen) on, use the b and -  (buttons 3 
and 4) to change the value from 0 to 1.  This will reverse the direction of the arrows 
on the Touch Screen.  Once changed,  turn off the RED LED on the menu button, 
and test the results.  You may need to change the direction of both LCD Touch 
Panels.  The Touch Panel that is plugged into Touch Panel A is going to be 
affected by the direction settings in the menu option under "A".  The Touch Panel 
that is plugged into Touch Panel B is going to be affected by the direction settings 
in the menu option under "B".     

Warning!!! 

 In this same menu option is a feature for reversing the MOTOR 

DIRECTION.  Never change this setting without consulting Dado Door.  Damage will 
result if you change the Motor Direction.

13

Summary of Contents for Door Master Controller

Page 1: ...Manual Copyright 2013 All rights reserved No unauthorized duplication distribution or online posting without prior written consent from Dado Door LLC Dado Door LLC and the Dado Logo are registered tr...

Page 2: ...Motor Driver Fault Error Troubleshooting 20 Advanced Motor Driver Fault Error Troubleshooting Cont d 21 Initial Calibration and Setup 22 Initial Calibration and Setup cont d 23 Error Messages 24 Error...

Page 3: ...roller contains a simple and easy to follow menu directory of settings When changing a setting they are stored permanently This manual will cover all aspects of the menu It is advised that the install...

Page 4: ...E fully open quickly turn off the power If the door begins the homing process towards the CLOSED position then the belt has been installed in reverse It is advised that when powering the system up for...

Page 5: ...formation needed to set up the parameters Buttons Explained Move up or down the Main Menu Add or subtract from a number or select Yes No fields CURSOR Cycle the cursor through a menu item with more th...

Page 6: ...gs Factory settings Do not change 4 BYPASS MODE If required at power ON the user can immediately PRESS and HOLD down the Setup Mode Button until the Main Menu appears this will bypass the diagnositcs...

Page 7: ...erial communication Port 8 RS485 interface duplicate for daisy chain Motor 3 Phase Power Leads Connection to the Brushless DC motor power using 26VDC is made with a 3 condutor 18G specially prepared c...

Page 8: ...y the port that will be used as a Locking Touch Screen inside the room Port A it typically the outside Touch Screen Auto Home Upon each power up the system automatically moves towards a Home switch wh...

Page 9: ...configured to receive input from any low voltage source for remote control such as a fire alarm contact closure PiNG Proximity Sensor Option The Ping Sensor is a small device offered by Dado Door that...

Page 10: ...system against overload due to an obstruction during the Homing phase The parameters may need to be adjusted to account for the weight speed and friction of each door by the user at the time of insta...

Page 11: ...ng thus a higher Trip Level will be required to avoid false trips Each time the speed is adjusted in the menu the Trip Levels will need to be adjusted as well for optimal retraction If you have set th...

Page 12: ...where the motor door are in a highly precision manner The Set Close Position value shown in the display will equate to approximately 1 500 As an example if the value says 5000 then calculate 5000 500...

Page 13: ...ressure on the door during the closing motion Above a certain pressure on the door the door will auto retract Closing Trip Level In some cases during the last couple of inches of travel closing as the...

Page 14: ...mber means the factor will be larger and will take longer to slow the door to a stop To cause the door to take longer to accelerate to full speed choose a higher accel factor Shorter values produce a...

Page 15: ...opposite direction while the arrows are pressed Due to the fact that there are numerous ways a system can be set up these arrows may not always reflect the direction that the door is actually moving i...

Page 16: ...ned on the offset value is used for the fully open position The value in the menu is approximately 1 500 So for example to create a 1 2 offset put the offset value at 250 The door should move as the s...

Page 17: ...controller The Destination number will always be 0 by default System Input Configuration The system controller has a number of options for controlling the door On the top of the enclosure are the con...

Page 18: ...attached to the motor that allows the system to know very precisely where the motor and door are at all times If the encoder has been damaged or the cable that connects the system controller to the m...

Page 19: ...Fault LED on the motor driver board is lit right away then there is a problem 1 The Motor Logic cable is not plugged in from the Master Controller to the motor 2 On the motor there is a set of five w...

Page 20: ...any wires out of a pair Each end of the CAT5 cable should be identical colors not mirrored colors When the connection problem is resolved on power up the motor driver board will only have the Green PW...

Reviews: