Each cord must be connected depending on its color.
When connecting different cord, attach color tube
around the connector. Connect the coupler to the con-
nector with same color and same pin number.
•
Identify the two-colored cord by main color first and
then striped color .
•
When measuring voltage or resistance of the cord ter-
minal using tester, contact the tester plug behind of the
coupler. Pay attention not to open the cord terminal
and contact the tester plug from the front of the cou-
pler in case of water-proof coupler.
•
Recheck the condition of contact, securing and conti-
nuity of each part after maintenance.
•
When connecting the battery, the plus terminal must
be connected first.
•
After connecting the terminal, apply the grease to the
terminal.
•
When disconnecting the battery, the minus terminal
must be disconnected first.
•
Make sure that the tool such as spanner do not contact
with the frame.
•
Connect covers to the terminal after maintenance.
•
If the fuse is short-circuited, find out the cause and
repair. Replace with the fuse having the specified
capacity.
•
If there is rust in the terminal, remove the rust with
sand paper prior to connecting.
CAUTION WHEN WIRING
BLACK CORD
WHITE
COUPLER.
WHITE
RED STRIPE
RED STRIPE
WHITE / RED CORD
TESTER PLUG
WHITE
TUBE
BLACK TUBE
VALIDATION
OF CAPACITY!
REMOVE
THE
RUST!
SERVICE INFORMATION
Summary of Contents for S3
Page 1: ...SM63 1010 01E...