 - If any foreign materials get on the device, first turn off the device and use a soft cloth to 
   wipe the device with a bit of water or a neutral detergent. 
   (It may cause discoloration, damage or malfunction.)

- If you sanitize product, first turn off the device and wipe off with soft cotton using neutral 
  detergent.
  (It may cause discoloration, damage or malfunction.)

- Be careful not to let liquid in the air socket in front of the product or the ac inlet at the back.
  Liquid inflow may affect the inner parts and cause malfunction, electric shock or fire.

- Do not wipe the device with benzene, thinner, alcohol, etc or spray water directly on the 
  device.
  (It may cause discoloration, damage, electric shock or fire.)

2-6. How to clean

2-6-1. How to clean the device

     Use neutral detergent or the alkalescence for cleaning. 
     Dilute in water if it is Alkali undiluted state. 
     Be careful the detergent not to enter into the skin or eyes. 

  *

- If any foreign material gets on the tubing, use a soft cloth to wipe the tubing with a bit of 
  water or a neutral detergent. 

- Be careful of any liquid doesn’t go into the tubing. 
  (It may cause the durability of the tubing if water is inside of the tubing, it could also break
  and cause a fire if and when water goes into the device from the tubing.)

- Do not spray water directly on the tubing or put the tubing into the water. 

- Do not wipe the device with benzene, thinner, alcohol, etc.

2-6-2. How to clean the tubing

- If any foreign material on the sleeve, use dried cloth or tissue to wipe the sleeve. 

- Use little bit of neutral detergent or water on a soft cloth and completely dry the sleeve.
  (It may cause decline the durability or modify when the sleeve is wet.)

2-6-3. How to clean the sleeve

 11

 

Summary of Contents for Doctor Life Lx9max

Page 1: ...for safety use Read this manual carefully This manual is for user s safety and previewing any property loss Before using our device please read this manual inevitably EN ISO 13485 2016 ISO 13485 2016...

Page 2: ...nditions 12 2 8 WEEE 13 3 Product package 3 1 Basic set 14 3 2 Accessories 15 3 3 Size of sleeve and zipper size 17 4 Product description 4 1 Device specifications 19 4 2 Device views 19 4 3 Appearanc...

Page 3: ...the chambers from 1st to 4th This user s manual contains the information how to use keep and repair this product Please be well informed of this manual to use this product correctly and to prevent the...

Page 4: ...eosynthesis or Joint Replacement in Lymphatic Paths Pacemaker Pulmonary embolism blood clot or edema Obscure Pain in Abdominal Area Pathological Pregnancy Tumorous Diseases Thrombophlebitis Inflammati...

Page 5: ...of fire and electric shock When the cord is damaged or this product is dropped and damaged do not operate this product To avoid the risk of electric shock use the power supply with protective groundin...

Page 6: ...l something abnormal while this product is in use immediately stop using this product In this case immediately turn off the power switch disconnect the power cord from the socket and contact the manuf...

Page 7: ...re is a risk of electric shock or current leakage which may cause fire When this product or the accessories is are damaged there is a risk of malfunction failure and fire which may cause injury Do not...

Page 8: ...not guarantee user safety 2 3 Cautions during use Do not apply extreme impact by dropping this product When moving this product make sure to turn off this product prior to moving it While this produc...

Page 9: ...this product and the accessories in a dry place free from water and moisture Moisture and liquid ingredients may damage the parts and circuits of this product Do not store this product in a dirty pla...

Page 10: ...pper on sleeve watch sticking of body hair or socks etc When this sleeve is not used for a long time clean this product and check whether or not this product functions properly prior to use Store this...

Page 11: ...se neutral detergent or the alkalescence for cleaning Dilute in water if it is Alkali undiluted state Be careful the detergent not to enter into the skin or eyes If any foreign material gets on the tu...

Page 12: ...mperature o C Relative humidity Atmospheric Pressure hPa Atmospheric Pressure hPa 2 7 Operating Storage condition 2 7 1 Operating conditions 2 7 2 Storage conditions Temperature o C Relative humidity...

Page 13: ...EE used by consumers and EEE internded for professional use Consumers have to actively contribute to the success of such collection and should be encouraged to return WEEE The Producer have to provide...

Page 14: ...3 1 Basic set Product package 3 LX9max Device Leg sleeve 1 Pair User manual Double tubing 14...

Page 15: ...Single tubing 3 2 Accessories Arm sleeve Center body sleeve Extension zipper Leg Arm Sleeve and tubing are articles of consumption 15...

Page 16: ...ER BODY EXT ZIPPER F 4ECGF01 OTHER SINGLE TUBING 1000370 DOUBLE TUBING 1000380 DISTRIBUTION TUBING 100050A Accessories Information Extension zipper accesory for separate sale When a sleeve is small to...

Page 17: ...kle Extension Extension zipper Length Girth Extension Length Extension zipper Size Thigh extension Ankle extension Length L 62cm 72cm 41cm 48cm 74cm XL 75cm 85cm 43cm 50cm 79cm XXL 76cm 86cm 46cm 53cm...

Page 18: ...Extension Center body sleeve dimension Girth Length Size Girth extension Length Free 108cm 118cm 74cm 18...

Page 19: ...Speed 1 6 level Mode A B C D Dimension 260 W x 180 D x 130 H mm Weight 2kg Only body Certification SAFETY IEC60601 1 EMC IEC60601 1 2 Ingress protection rating IP21 Product description 4 4 1 Device sp...

Page 20: ...4 Control knob Knob that control the operational pressure time speed of the device 5 Setting mode display A button that sets the mode A B C D 6 Skip care touch button display A button that sets or re...

Page 21: ...leeve to the device with the connectable tubing s 6 Turn on the power button at the top of the device 7 Set the operation time mode speed and pressure degree by pushing the button on the top of the de...

Page 22: ...e of air leakage from the sleeve or disconnection the tubing from the cap the sensor pressurizes about 90 sec and then progresses to next channel A beginner must start to use the device with the lowes...

Page 23: ...In A mode each chamber is inflated one by one from foot to thigh then deflate 6 times All sleeves are composed of 4CH and operate the same according to each mode 23...

Page 24: ...ously inflated and deflated In C mode inflation is applied twice in forward direction from foot to thigh and then once in reverse direction In B mode all chambers from foot to thigh are sequentially i...

Page 25: ...et up during the operating Plug in the tubing to the air socket Be careful with the direction of the plug Use single tubing when wearing one sleeve Use double tubing when wearing center body or two sl...

Page 26: ...is not bent 5 Air is going through the tubing in the wrong order Connection fault Check that the plug is correctly inserted into the outlet No Problem Cause Solution 1 Weak air comes out Damaged tubi...

Page 27: ...0 4 2 2008 Operating Stand by Enclosure AC 120V 60Hz AC 220V 60Hz AC 230V 50Hz 8 kV Contact 2 4 8 15 kV Air Radiated RF Electromagnetic Field Immunity EN 61000 4 3 2006 A2 2010 IEC 61000 4 3 2006 A2 2...

Page 28: ...and by Enclosure AC 120V 60Hz AC 220V 60Hz AC 230V 50Hz 30 A m 50 Hz 60 Hz Voltage dips EN 61000 4 11 2004 IEC 61000 4 11 2004 Operating Stand by AC Mains AC 100V 50HZ AC 100V 60HZ AC 127V 50HZ AC 127...

Page 29: ...with marking bar EN 50419 Type BF applied part IEC 60878 5333 Increase Direction Custom Symbol Decrease Direction Custom Symbol ON OFF IEC60878 5009 Run Graphical Custom Symbol Symbol recommending the...

Page 30: ...5 3 4 Consult instructions for use ISO 15223 1 5 4 3 Refer to instruction manual ISO 7010 M002 Stacking limit by Number ISO 7000 2403 Humidity limitation ISO 15223 1 5 3 8 Temperature limit ISO 15223...

Page 31: ...Digital System Custom Symbol Low noise design Custom Symbol Easy Operation Custom Symbol Wide Pressure Range Custom Symbol 31...

Page 32: ...MEMO 32...

Page 33: ...MEMO 33...

Page 34: ...MEMO 34...

Page 35: ...s careless use or in case of followings even though warranty period 1 Disorder happened by strong impact 2 In case user repair or reproduce internal part arbitrarily 3 In case of using the device in p...

Page 36: ...rded the Governor s Citation for Day of Commerce and Industry by Gyeonggi province 2011 President Award Gold Listed at the Korea Precision Industry Technology Contest 2012 Selected an Global Small Gia...

Reviews: