7-10
FAULTY DIAGNOSIS
How to handle
Cause
The door opens right after the door is closed, or the door will not open after overladed closing.
Rotation cam setting is faulty
Set them in a way that the center of the roller and rotation
cam edges Are on the same line.
How to handle
Cause
Door operation feels weak
Faulty air pressure
Basic reaction setting is faulty
Check if air pressure is higher than 6kgf/cm
2
and adjust it to
6~9kgf/cm
2
if different.
Arrange them so that they are lined with the marking line by
turning universal shafts. (Basic reaction value : 75kgf)
How to handle
Cause
The upper part of the door (locking) is stuck on the body and the swing door won
’
’
t open
Guide arm balance is faulty
The door will drop 15mm and turn when opening. Press the
front part of the door so that the rear part is opened first.
Adjust the guide arm while the door is open to balance the
door. (Extend the lever)
The door and body locking is faulty, making it shake
Adjust the air pressure.
Adjust the reaction setting.
How to handle
Cause
Strange noises from the door while driving