6. METHODS OF EXCHANGING MAIN PARTS
(1) Freezing room louver
1) Unscrew, remove the F-louver by
pulling forward with inserting
screwdriver into the hole of F louver.
2) Assemble it by pressing triangle
shape ( ) by hand.
(2) Multi-Duct
1) Disassemble the R-Window by inserting a
finger in the lower part and pulling forward
while pushing upward slightly.
* When assembling, fit the lower part of
the R-Window first, then press the top
part until it fits.
WINDOW R
2) Use a "+" driver to unscrew 4 screws.
3) Hold the multi duct assembly damper
part with hand and pull forward instantly
and disconnect a housing.
-5-