19
8. To remove fan motor assembly.
(1) Remove two screws
¤
which secure the back ocver
¤Ł
from the cavity outer.
(2) Remove two screws
¤Ø
which secure the fan motor
¤Œ
from the back cover
¤Ł
.
(3) Pull out the fan
¤º
from the motor
¤Œ
.
(4) Reverse the above steps for reassembly.
9. To remove transformer.
(1) Remove the four screws
¤
holding the H.V.
transformer
¤Ł
.
(2) Remove the transformer
¤Ł
.
(3) Reverse the above steps for reassembly.
CAUTION : Never install the magnetron without the metallic gasket plate which is packed with each
magnetron to prevent microwave leakage.
Whenever repair work is carried out on magnetron, check the microwave leakage.
It shall not exceed 4mW/cm
2
for a fully assembled oven with door normally cosed.
Magnetron
antenna
Metallic
gasket
plate
Cooling fin
Filament
terminal
Magnetron
Wave guide
Magnetron antenna
Metallic gasket plate
2
1
1
3
1
5
4
2
Summary of Contents for KOR-61852S