21
(TROUBLE 4)
The following visual conditions indicate a profective touch control circuit or membrane switch assembly.
1. Incomplete segments,
1) Segments missing.
2) Partical segments missing.
3) Digit flickering other than normal display slight flickering.
4) “:0” does not display when power is on.
2. A distinct change in the display is not on when it should be.
3. One or more digits in the display are not on when they should be.
4. Display indicates a number different from one touched.
5. Specific numbers (for example 2 or 3) will not display when the panel is touched.
6. Display does not count down or up with time cooking or clock operation.
7. Oven is programmable and cooks normally but no display shows.
8. Display obviously jumps in time while counting down.
9. Display counts down noticeably too fast while cooking.
10. Display does not show the time of day when clear pad is touched.
11. Oven lamp and turntable motor do not stop although cooking is finished. Check if the RELAY 2 contacts close if they are
close, replace touch control circuit.
TROUBLE SHOOTING GUIDE
Before following the particular steps listed above in the trouble shooting guide for the membrane keyboard’s, failure, please
check for the continuity of each wire-harness between the membrane keyboard and P.C.B. assembly.
NOTE
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Display does
not show
programming
at all, even if
keyboard is
touched.
Normal
Replace
control box
sub-assembly
Replace the
membrane
keyborad
Malfunction
of touch
control circuit
of control box
sub-assembly
Abnormal
Check each pad for
continuity of the
membrane keyboard
for the following
keyboard check
procedure
Malfunction of
the membrane
keyboard
M/W
DEF.
Lock
g
Summary of Contents for KOR-637V
Page 5: ...4 EXTERNAL VIEW 1 OUTER DIMENSION ...
Page 27: ...26 WIRING DIAGRAM ...
Page 29: ...MP1 28 PRINTED CIRCUIT BOARD MP2 ...
Page 30: ...29 PRINTED CIRCUIT BOARD ...
Page 32: ...31 2 P C B CIRCUIT DIAGRAM PRINTED CIRCUIT BOARD ...