PRODUCT SAFETY SERVICING GUIDELINES FOR COLOR TELEVISION RECEIVERS
CAUTION : Do not attempt to modify this product in any way. Unau-
thorized modifications will not only void the warranty, but may lead to
your being liable for any resulting property damage or user injury.
Service work should be performed only after you are thoroughly
familiar with all of the following safety checks and servicing
guidelines. To do otherwise, increases the risk of potential hazards
and injury to the user.
SAFETY CHECKS
After the original service problem has been corrected, a check should
be made of the following:
SUBJECT : FIRE & SHOCK HAZARD
1. Be sure that all components are positioned in such a way as to
avoid possibility of adjacent component shorts. This is especially
important on those chassis which are transported to and from the
repair shop.
2. Never release a repair unless all protective devices such as insula-
tors, barriers, covers, shields, strain reliefs, and other hardware
have been reinstalled per original design.
3. Soldering must be inspected to discover possible cold solder
joints,frayed leads, damaged insulation (including A.C. cord),
solder splashes or sharp solder points. Be certain to remove all
loose foreign particals.
4. Check for physical evidence of damage or deterioration to parts
and components, and replace if necessary follow original layout,
lead length and dress.
5. No leads or components should touch a receiving tube or a resistor
rated at 1 watt or more. Lead tension around protruding metal sur-
faces must be avoided.
6. All critical components such as fuses, flameproof resistors, capaci-
tors, etc. must be replaced with exact factory types. Do not use
replacement components other than those specified or make
unrecommended circuit modifications.
7. After re-assembly of the set always perform an A.C. leakage test
on all exposed metallic parts of the cabinet, (the channel selector
knob, antenna terminals, handle and screws) to be sure the set is
safe to operate without danger of electrical shock. Do not use a
line isolation transformer during this test. Use an A.C. Voltmeter,
having 5000 ohms per volt or more sensitivity, in the following
manner : connect a 1500 ohm 10 watt resistor, paralleled by a 15
mfd. 150V A.C. type capacitor between a known good earth
ground (9water pipe, conduit, etc.) and the exposed metallic parts,
one at a time. Measure the A.C. voltage across the combination of
1500 ohm resistor and 0.15 MFD capacitor. Reverse the A.C. plug
and repeat A.C. voltage measurements for each exposed metallic
part. Voltage measured must not exceed 0.75 volts R.M.S. This
corresponds to 0.5 milliamp A.C. Any value exceeding this limit
constitutes a potential shock hazard and must be corrected imme-
diately.
GRAPHIC SYMBOLS :
The lightning flash with arrowhead symbol,within
an equilateral triangle, is intended to alert the
service personnel to the presence of uninsu-
lated “dangerous voltage” that may be of suffi-
cienty magnitude to constitute a risk of electric
shock.
The exclamation point within an equilateral tri-
angle is intended to alert the service personnelto
the presence of important safety informationin
service literature.
Fuse symbol is printed on pcb adjacent to the
fuse, with “RISK OF FIRE REPLACE FUSE AS
MARKED”. The symbol is explained in the ser-
vice manual with the following wording or equiv-
alent.
“CAUTION : FOR CONTINUED PROTECTION AGAINST FIRE
HAZARD, REPLACE ONLY WITH SAME TYPE (5A, 125V)” and
“ATTENTION: AFIN D’ASSU UNE PROTECTION PERMANENTE
CONTRE LES RISQUES D’INCENDIE, REMPLACER UNIQUE-
MENT PAR UN FUSIBLE DE MEME TYPE ET DE ”5A, 125V”.
SUBJECT : X-RADIATION
1. Be sure procedures and instructions to all service personnel cover
the subject of X-rays in current T.V. receivers is the picture tube.
However, this tube does not emit X-rays when the high voltage is
at the factory specified level. The proper value is given in the appli-
cable schematic. Operation at higher voltages may cause a failure
of the picture tube or high voltage supply and, under certain cir-
cumstances, may produce radiation in excess of desirable levels.
2. Only factory specified C.R.T. anode connectors must be used.
Degaussing shields also serve as X-ray shield in color sets.
Always re-install them.
3. It is essential that the serviceman has available an accurate and
reliable high voltage meter. The calibration of the meter should be
checked perio - dically against a reference standard. Such as the
one available at your distributor.
4. When the high voltage circuitry is operating properly there is no
possibility of an X-radiation problem. Every time a color chassis is
serviced, the brightness should be run up and down while monitor-
ing the high voltage with a meter to be certain that the high voltage
does not exceed the specified value and that it is regulating cor-
rectly. We suggest that you and your service organization review
test procedures so that voltage regulation is always checked as a
standard servicing procedure. And that the high voltage reading be
recorded on each customer’s invoice.
5. When troubleshooting and making test measurements in a receiver
with a problem of excessive high voltage, avoid being unnecessarily
close to the picture tub eand the high voltage compartment.
Do not operate the chassis longer than is necessary to locate the
cause of excessive voltage.
6. Refer to HV, B+and Shutdown adjustment procedures described in
the appropriate schematic and diagrams(where used).
10WATT
Good earth ground,
such as the water
pipe, conduit, etc.
1500 OHM
A.C. VOLTMETER
Place this probe
on each exposed
metal part.
0.15 uF
1. SAFETY INSTRUCTION
Summary of Contents for DDQ-20L6SC
Page 11: ...5 SCHEMATIC DIAGRAM 10 5 1 MAIN CIRCUIT DIAGRAM ...
Page 12: ...SCHEMATIC DIAGRAM 11 5 2 POWER CIRCUIT DIAGRAM ...
Page 22: ...7 PRINTED CIRCUIT BOARD 21 7 1 PCB MAIN ...
Page 23: ...PRINTED CIRCUIT BOARD 22 7 2 PCB POWER ...
Page 24: ... 23 9 IC DESCRIPTION U COM I701 9 1 U COM I701 PIN ASSIGN ...
Page 27: ... 26 10 CHIP COMPONENTS POSITION PCB MAIN ...
Page 41: ......