l. Assemble the nozzle and nozzle
holder assembly to the nozzle tester
(105785-1010). (Figure 4-33)
- 113 -
0
20
40
60
80
100
EQM4039I
<Figure 4-33> Nozzle test, nozzle and nozzle
holder assembly
m. Adjust the primary opening pres-
sure to the specified pressure
using the adjusting screw(4).
(Figure 4-34)
EQM4040I
<Figure 4-34> Adjusting the primary opening
pressure
n. With a monkey wrench, fix the
nozzle holder securely and tighten
the cap nut(SW19mm) to speci-
fied torque. (Figure 4-35)
Cap nut tightening torque :
29~39N•m (3.0~4.0kg•m)
EQM4041I
<Figure 4-35> Tightening cap nut