- 160
-
Assembly
Part
Check items
Nominal Standard value
Limit for
Correction
Remarks
value
forassembly
use
Radiator & water pump for corrosion, damage & improper connecting
-
-
-
Correct or replace
Test for leakage(air pressure) kg/cm
2
-
1.0332
-
Submerge in water and replace if air bubbles found
Radiator
Pressure valve for opening pressure kg/cm
2
-
0.5
-
Negative pressure valve for opening pressure mmHg
-
20
-
Pump speed 2,500rpm
Cooling Water Delivery volume l/min
Water temp 24
C
Approx. 314
system pump
Negative pressure 1.0bar
Clearance between pump impeller & pump body
-
0.3~0.6
-
Replace if contacted impeller and pump body
Operating temperature(permissible temp.)
C
-
90~95
95
Temperature above this not
Permissible temperature in a short time
C
-
105
105
allowable
Thermostat opening temp.
Thermostat
(under atmospheric pressure)
C
-
83
-
Replace if defective
Full opening temp.
C
-
95 or lower
-
Stroke : minimum 8mm
Compression pressure Cylinder compression pressure (kg/cm
2
)
28 or higher 24~28 or higher 24 or higher Overhaul the engine
at 200 rpm or more
Piping Fuel pipe, injection pipe & Nozzle holder for
and the damage, cracks, looseness, bad packing
Correct or replace
other
Fuel filter element for damage
Clean or replace
Fuel
Injection pressure of injection nozzle (kg/cm
2
)
220
Adjust by shim
Ti Engine 1st : 160, 2nd : 220
System Opening pressure of overflow valve (kg/cm
2
)
Replace valve
Height of projected nozzle on the cyl. head (mm)
4.3
Replace cyl. head and nozzle
Clearance between injection pump coupling and timer (mm)
0.2~0.4
Correct electrical device if
Electric
Warning lamp
unusual sound
Devices
Oil
The terminal of electric wire for
filter
loosening, short, or damaged
Correct
Cooling
water
temp
Charging
and
discharging
indication