Location Requirements
To ensure proper ventilation for your ice maker, the front of the unit must be
completely unobstructed. Allow at least 150 mm clearance at rear, and 40 mm
at top and sides for proper air circulation. The installation should allow the ice
maker to be pulled forward for servicing if necessary.
When installing the ice maker under a counter, follow the recommended spacing
dimensions shown. Place electrical and water supplies and drain fixtures in the
recommended locations as shown.
Choose a well-ventilated area with temperatures above 13
℃
and below 32
℃
.
This unit MUST be installed in an area protected from the elements, such as wind,
rain, water spray or drips.
The unit should not be located next to ovens, grills or other sources of high heat.
Installation of the ice maker requires a cold water supply inlet of 19mm O.D.
soft copper tubing with a shut-off valve. A gravity-drain system provided with the
unit can be used.
(NOTE: Runoff water can also be drained into a sink via a pump – not included –
when a gravity drain is not available.)
The ice maker requires a continuous water supply with pressure between 0.1Mpa
and 0.5Mpa. The temperature of the water feeding into the ice maker should be
between 5
℃
and 25
℃
for proper operation.
Installation clearance
top view (1:10) (mm)
Side view (mm)
Rear of unit
Front of unit
Side
40
40
150
40
40