- 55 -
I810
C O N T R O L L E D
RECTIFIER
R820
R830
C830
R829
Q808
6V DC
Q809
Q807
HIGH
HIGH
HIGH
L O W
POWER
L O W
I810 controlled rectifier switching circuit
* TV set stand-by mode operations
-On stand-by mode, I501 microcontroller pin 63 (power) is set to low.
- So, Q809 collector is set to high.
-Then, I810 controlled rectifier gate pin is set to high and I810 is conducting.
- So, current flows from pin 16 SMPS transformer to the ground via I804 optocoupler and Q810 and
Q811 transistors (which are conducting).
- In these conditions, I801 delivers pulses on light mode and T801 produces voltages with reduced
power.
- As I810 is conducting, current flows also from pin 16 SMPS transformer to I823 (3.3V regulator) for
I501
µ
com, IR receiver and front mask buttons supply voltage (then, remote control or front mask
buttons can be activated to leave stand-by mode).
Summary of Contents for DTA-20 T1
Page 17: ...Service manual CP 385 CP785 16...
Page 21: ...Service manual CP 385 CP785 20...
Page 34: ...Service manual CP 385 CP785 33 5 Circuit description 5 1 Block diagram...
Page 39: ...Service manual CP 385 CP785 38 Chassis block diagram IF...
Page 43: ...Service manual CP 385 CP785 42 Sound signal flow diagram...
Page 70: ...69 Service Manual cp 385 cp 785 7 Exploded View 7 1 DTA 20T1...
Page 73: ...72 7 4 DTA 20T8 Service Manual cp 385 cp 785...
Page 74: ...73 7 5 DTA 21T1 Service Manual cp 385 cp 785...
Page 76: ...75 7 7 DTA 21T5 Service Manual cp 385 cp 785...
Page 77: ...76 7 8 DTA 21T9 Service Manual cp 385 cp 785...
Page 79: ...78 Service Manual cp 385 cp 785 7 10 DTE 25G6...
Page 80: ...79 Service Manual cp 385 cp 785 7 11 DTE 25G7...
Page 82: ...81 7 13 DTE 28G6 Service Manual cp 385 cp 785...
Page 90: ......
Page 91: ......