6. Y REC CURRENT
• Adjustment Procedure
1. Set the TV/LINE to LINE mode.
2. Supply the color bar signal to video input jack.
3. Set the VCR to the stop mode.
4. Connect the oscilloscope to check point and trigger the scope with CH1.
5. Adjust R399 to obtain 300±10 mV (at the position of SYNC)
• Adjustment Inspection Standard: 300±10 mV (at the position of SYNC)
9
Mode
Adjustment Parts
Check Point
Test Equipments
Test Tape
Input Signal
LINE INPUT
CH1: TJ313
Signal Gen.
& STOP
(
R399
CH2: TJ399
Oscilloscope
Color Bar
Location of Adjustment Parts
Observation Waveform
H-Axis: 10us/div
V-Axis: 50mv/div
MAIN PCB
T
U
N
E
R
HEAD-AMP
DECK
8
1
6
3
7
4
5
2
10
9