2
+
-
Display
Inflation
ON / OFF
Air Hose
Torch / USB
Charging
Switch
Charging
Connector
USB
Connector
Battery Level
Indicator
Fault
Indicator
Valve
Adaptor
Pressure
Unit
Increase
Pressure
Decrease
Pressure
+
-
1. SAFETY
Read and understand this user guide before using the equipment. Retain the user guide for future
reference.
Any damage or equipment failure due to incorrect usage is not covered by warranty.
• Always wear approved safety goggles when working with tools and equipment.
• When inflating tyres etc, do not exceed the pressures recommended by the manufacturer.
• Do not submerge the device as damage to the unit may occur.
• Always monitor inflation to avoid over-inflation or bursting of the inflated item.
• If inflation time exceeds 3 minutes be aware that some parts of the device may become hot.
Overview and Controls
The product is designed for general domestic inflation tasks, and includes additional functions:
• Standard vehicle 12VDC charging (charging cable / adaptor included).
• Programmable inflation pressure - automatically stops when required pressure is reached (Schra-
der type
plus 3 additional valve adaptors included).
• Charging/powering USB devices.
• Battery charge indicator.
• Torch function.
2. OPERATION
Note:
Before use, ensure that all parts have been supplied and the battery is fully charged. Initial
charge may take up to 48 hours.
Charging the Battery
1. Connect the supplied charging cable to a standard 12VDC vehicle socket.
2. Connect the other end of the cable to the compressor Charging Connector.
3. When charging, the Battery Level Indicator flashes.
4. When fully charged, all 4 indicator lights will illuminate and remain on.
Using the Compressor for Inflation
1. Unclip the Air Hose from the unit. Unlock and securely connect the Valve Adaptor to the valve of
the item to be inflated (X), then lock the adaptor. If required, attach the necessary adaptor into the
Valve Adaptor.
2. Press the Inflation ON / OFF button to turn the unit on.
3. Press the Increase Pressure / Decrease Pressure buttons as required until the desired pressure is
shown in the Display. If required, press the
Pressure Unit button to change the unit of measurement between PSI,
Bar, KPa and kgf.
4. Press the Increase Pressure / Decrease Pressure buttons simultaneously to save the pressure
setting.
5. Press the Inflation ON / OFF button to turn the compresor on. When the pressure is reached, the
compressor automatically stops. Disconnect the Valve Adaptor quickly from the inflated item to
avoid pressure loss. The unit will switch off automatically after 15 seconds.
Using the Torch / Flashlight
1. Press and hold the Torch / USB Charging button for 3 seconds to switch the torch light on.
2. When finished, press the Torch / USB Charging button once to switch the torch light off.
Using the USB Charger
1. Connect the USB device to the USB Connector using a standard USB cable (not supplied). The
battery must be charged to use this function.
2. Press the Torch / USB Charging button once to switch the USB charging function on. If the unit
has been used within the last 48 hours, USB charging is automatic on conneciton of the cable - no
need to press the Torch / USB Charging button.
3. When finished, disconnect the USB cable from the USB Connector.
Fault Indicator
The Fault Indicator may illuminate if the unit reaches an over-temperature or over-current state.
When in a fault state all functions are not available. When the indicator is off, the unit can be used
again.
3. TECHNICAL SPECIFICATIONS
Max pressure: 10.3 atm
Current consumption (in work): 4~7 A
Current consumption (sleep mode): <50 A
Flashlight: <150 mA / USB: < 1.5 A
USB output: 5 V/max: 1 A
Charger voltage: 9~30 V
Charger current: < 2 A
Battery capacity: 3000 mAh