Optical Interlinked Smoke Alarm 

Model No. ELA1380 

User Manual 

IMPORTANT 

 RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE 

Description of Parts 
 

 
 
 

 
 
 

 
 
 
 

 
 

 

 
 

 

 

 
 

 

IMPORTANT: 
Please read these instructions thoroughly before use and retain for future 

reference. 

The alarm will not attach to the mounting bracket unless battery is installed 
correctly. 

Removal of battery will render the smoke alarm inoperative.

 

 

Smoke alarms can provide early warning of possible fires.  

 

Recommended Locations for Smoke Alarms 

 

It is recommended to install one alarm in each room 

 see diagram below right. 

 

As a minimum, locate an alarm in the immediate area of bedrooms (i.e. 

landings). 

 

Locate additional alarms to monitor any stairways as stairways act as a chimney 

for smoke and heat.

 

 

 

Mount the alarm on the ceiling in the centre of the room, this places it closest to 
all points in the room  

 

When mounting an alarm on the ceiling, locate it a minimum of 50cm (20 inches) 
from the wall 

 see diagram below left. 

 

When mounting the alarm on a wall use an inside wall with the top edge of the 
alarm at a minimum of 50cm (20 inches) below the ceiling. 

 

The smoke alarm should be mounted at least 150cm away from lights, exhaust 
fans, air conditioning units, air inlet/outlets, etc. 

 

Mounting 

Plate 

Mounting 
Hole 

Mounting 

Hole 

Battery 

Compartment 

Sounder 

Test/Hush Button 

and LED Indicator 

CR123A Battery 

Wall Plug (x2) 

Screw (x2) 

Double Sided 

Sticky Pad 

Summary of Contents for ELA1380

Page 1: ...1 Optical Interlinked Smoke Alarm Model No ELA1380 User Manual IMPORTANT RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Optical Interlinked Smoke Alarm ELA1380 User Manual...

Page 2: ...the immediate area of bedrooms i e landings Locate additional alarms to monitor any stairways as stairways act as a chimney for smoke and heat Mount the alarm on the ceiling in the centre of the room...

Page 3: ...ensation Smoke alarms should not be installed within 3ft 0 9m of the following the door to a kitchen the door to a bathroom containing a bath or shower forced air supply ducts used for heating or cool...

Page 4: ...fixing holes using the mounting plate as a guide Drill two holes with a 4mm Masonry drill bit not supplied NB The distance between the two holes is 42mm Insert the plastic plugs into the holes Pass t...

Page 5: ...icator will flash quickly three times to show the two alarms are now linked together The LED indicator will then begin to flash slowly 5 The LED indicator on the first alarm will stop flashing NB The...

Page 6: ...the LED indicator and will flash twice Hush State Once the alarm sounds press the test button to enter the alarm hush state the alarm will not sound for 9 minutes however if the smoke concentration i...

Page 7: ...batteries are removed if the alarm is not to be used for a long period of time or if the alarm is to be disposed of Replace only with the same or equivalent battery type Do not expose batteries to su...

Page 8: ...ropriate plastics collection service Disposal of the Product You should now recycle your waste electrical goods and in doing so help the environment This symbol means waste electrical products at the...

Page 9: ...9 Optical Interlinked Smoke Alarm Model No ELA1380 User Manual IMPORTANT RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE...

Page 10: ...TURE REFERENCE Daewoo Electricals is a registered trademark Imported by ESG Ltd Manchester M3 1JS EU Rep EuroSonic Magppie ESM Ltd Ireland D05 X006 www esgltd com Produced by Chongqing Zorro Alert Tec...

Reviews: