Locations to Avoid Mounting Your Smoke Alarm 

 

Less than 50cm (20 inches) from the peak of an A 

frame type ceiling. 

 

In an area where the temperature may fall below 

0˚C (32˚F) or rise above 40˚C (104˚F), such as 

garages or unfinished attics. 

 

Do not install the alarm in a bathroom or places 
that are prone to condensation. 

 

Smoke alarms should not be installed within 3ft 

(0.9m) of the following: the door to a kitchen, the 
door to a bathroom containing a bath or shower, 
forced air supply ducts used for heating or cooling, 

ceiling or whole house ventilating fans or other 
high air flow areas. 

 

Near fluorescent lights including CFL lamps. Electronic 

“noise” may cause false alarms.

 

 
 

 

Left

: Ensure the Smoke Alarm is 

positioned at least 50cm (20 inches) 

away from a wall when mounting it on 

the ceiling and 50cm (20 inches) below 

the ceiling when mounting it on a wall. 

Recommended positions of smoke alarms: 

 

Single Storey Buildings 

Multi Storey Buildings 

Summary of Contents for ELA1380

Page 1: ...1 Optical Interlinked Smoke Alarm Model No ELA1380 User Manual IMPORTANT RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Optical Interlinked Smoke Alarm ELA1380 User Manual...

Page 2: ...the immediate area of bedrooms i e landings Locate additional alarms to monitor any stairways as stairways act as a chimney for smoke and heat Mount the alarm on the ceiling in the centre of the room...

Page 3: ...ensation Smoke alarms should not be installed within 3ft 0 9m of the following the door to a kitchen the door to a bathroom containing a bath or shower forced air supply ducts used for heating or cool...

Page 4: ...fixing holes using the mounting plate as a guide Drill two holes with a 4mm Masonry drill bit not supplied NB The distance between the two holes is 42mm Insert the plastic plugs into the holes Pass t...

Page 5: ...icator will flash quickly three times to show the two alarms are now linked together The LED indicator will then begin to flash slowly 5 The LED indicator on the first alarm will stop flashing NB The...

Page 6: ...the LED indicator and will flash twice Hush State Once the alarm sounds press the test button to enter the alarm hush state the alarm will not sound for 9 minutes however if the smoke concentration i...

Page 7: ...batteries are removed if the alarm is not to be used for a long period of time or if the alarm is to be disposed of Replace only with the same or equivalent battery type Do not expose batteries to su...

Page 8: ...ropriate plastics collection service Disposal of the Product You should now recycle your waste electrical goods and in doing so help the environment This symbol means waste electrical products at the...

Page 9: ...9 Optical Interlinked Smoke Alarm Model No ELA1380 User Manual IMPORTANT RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE...

Page 10: ...TURE REFERENCE Daewoo Electricals is a registered trademark Imported by ESG Ltd Manchester M3 1JS EU Rep EuroSonic Magppie ESM Ltd Ireland D05 X006 www esgltd com Produced by Chongqing Zorro Alert Tec...

Reviews: