Maintenance Section
-179-
Every 1000 Service Hours or 6 Months
You must read and understand the warnings and instructions contained in the Safety section of this manual,
before performing any operation or maintenance procedures.
Hydraulic Return Filter, Breather
& Strainer - Check, Change
WARNING
Hot oil and components can cause personal
injury. Do not allow hot oil or components to
contact skin.
Park the lift truck level with the forks lowered,
parking brake engaged, transmission in NEUTRAL
and the engine stopped.
1.
Loosen the bolts of the hydraulic tank top plate
assembly.
2.
Remove the return filter from tank top plate
assembly.
3.
Install new return filter by hand.
4.
Remove the suction strainer from the tank.
5.
Install the new strainer by hand.
6.
Install the tank top plate assembly and fasten
the bolts.
Typical Example
7.
Remove and discard the air breather.
8.
Install a new air breather.
9.
Start the engine and operate the hydraulic
controls, and the steering system, through a
few cycles to fill the lines. Look for oil leaks.
10.
Stop the engine and check the oil level. With all
cylinders retracted, maintain the oil level to the
FULL mark on the dipstick/filter cap assembly.